background image

 

Page 10 of 11 

 

NPPA-TT-IDC Instruction Manual

 

 

Alternatively the jack pairs may be pulled out by the use of 
two Bantam plugs (diagonally plugged in). 

 

 

The two jack pairs have to be re-assembled in the right way 
so that the thicker body marked “left” is put on the left side 
with the mark outside and readable. 
 

 
To complete, push the new jack pairs into the casing again with the mark on the left side (If 
more than one module are removed always assemble from the center to the right or left side 
and be careful that the keys on the left side of the jack pairs find their guiding slots. If all jack 
pairs are removed start at the casing support in the center and assemble to the right and left 
side). Slide in again the channel identification strips (best from the outside inwards) and fix the 
front panel with the black cross-recessed screws. Don’t forget to insert the side-stops before 
fixing the screws. 

Содержание NPPA-TT-IDC

Страница 1: ...811 441 Tel 1 732 901 9488 Tel 81 3 3663 4733 Tel 33 1 4131 6750 Tel 49 8131 28 08 90 Fax 423 232 53 93 Fax 41 44 736 5011 Fax 44 1983 811 439 Fax 1 732 901 9608 Fax 81 3 3663 4796 Fax 33 1 4131 0511...

Страница 2: ...lectrical configuration 3 2 Grounding variations 4 3 Wiring 5 4 Cable retention 7 5 Channel identification 7 6 Replacement 9 7 Technical data 11 8 Content of supply 11 Dimensional Drawings Easy Patch...

Страница 3: ...and featuring precision aluminum fittings it is built to last The Neutrik Easy Patch is suitable for analog and digital audio signals The Easy Patch is available in five normalling configurations full...

Страница 4: ...the Top and Bottom PCB bus by connecting the solder pads The connection between Top and Bottom bus is made by jumpers Chassis The same as Central but with jumpers connecting the Top and Bottom row bu...

Страница 5: ...remove the top cover with three cross recessed screws M2 5x8mm IDC terminals with gas tight connection enable fast and easy wiring No soldering or fixing with screws is necessary For wiring please us...

Страница 6: ...lot 0 40 mm 0 65 mm 2 0 65 mm 0 90 mm 1 When using wire in the range of 0 4 to 0 65mm diameter the modules allow up to two identical wires of the same diameter to be terminated in one contact It is no...

Страница 7: ...le It is attached to the casing with four screws 5 Channel identification The front panel is equipped with channel identification strips located in the center of the channels and marked with the chann...

Страница 8: ...ull out the side stop the transparent foil and the paper strip itself After marking is done assemble the parts in reversed sequence Remove labeling strip Side Stop NOTE For easy and perfect marking yo...

Страница 9: ...while the panel is on air For replacement simply remove the easy accessible jack pairs Module consisting of 2 Jack Pairs Remove Front Panel by unscrewing the 3 black cross recessed screws M3x8 Taptit...

Страница 10: ...e casing again with the mark on the left side If more than one module are removed always assemble from the center to the right or left side and be careful that the keys on the left side of the jack pa...

Страница 11: ...ange 30 C to 80 C 7 3 Materials Jack housing PA 66 blend Jack contacts CuSn6 TRIBOR plated 0 2 m AuCo over 2 m NiP Casing Steel and aluminum black coated Front Panel AlMgSi 0 5 F22 8 Content of supply...