background image

NX-507E / NX-508E AUXILIARY MODULES

 

 

11

 

Location 33 

Programming the Closing Time for Schedule 1 

(2 segments of numerical data) 

 

Segment 1

 

Program the hour of the closing time in 24-hour format.  (1:00 PM = 13) 

Segment 2

 

Program the minutes after the hour of the closing time for Schedule 1. 

 

Location 34 

Programming the Days for Schedule 1 

(1 segment of numerical data) 

 

LED DESCRIPTION 

"On" if the schedule is active on Sunday. 

"On" if the schedule is active on Monday. 

"On" if the schedule is active on Tuesday. 

4 “

On" if the schedule is active on Wednesday. 

"On" if the schedule is active on Thursday. 

"On" if the schedule is active on Friday. 

“On" if the schedule is active on Saturday. 

"On" if the schedule is disabled on holidays. 

        

Locations 35 - 55  Programming for Schedules 2-8 

(2 segments of numerical data)  Locations 35 - 55 are used to program the opening times, closing times, and 

days for Schedules 2 - 8.  Each schedule has three locations that are programmed with the same steps as 

Schedule 1 described previously.  Refer to Schedule 1 (locations 32 - 34 above) for specific instructions and the 

worksheets beginning on page 14. 

 

Location 56 

Programming the Date of Holidays in January 

(8 segments of numerical data)  Program the day of the month in January that the Opening time in a schedule is 

suppressed.  For example, if the opening should not occur on January 1, program a "1" in Segment 1.  This 

feature can be repeated up to a maximum of 8 holidays per location (month). 

 

Locations 57-67  Programming the Date of Holidays from February to December 

(8 segments of numerical data)  Locations 57 - 67 are used to program the day of each month, from February to 

December, in which the Opening time in a schedule is suppressed.  Each location will accommodate up to a 

maximum of 8 holidays, and programmed with the same steps as Location 56 described previously.  Refer to 

worksheets. 

 

Locations 68-91  Authorizing Users for Outputs 1-8 

(10 segments of binary data)  When activating outputs with a user code (event #45), locations 68-91 can be used 

to restrict certain codes from activating certain outputs.  At factory default, all users have full authorization.   

Each location contains 10 segments.  The LEDs correspond to outputs 1 - 8.  Refer to Table X-1 on page 12

 

Location 68 

Authorizing Users 1-10 

  Segment 1 corresponds to user 1; Segment 10 corresponds to user 10.     

NOTE

: To use locations 68-91, a “0” must be programmed in segment 2 (zone/user) of the 

corresponding output.  Refer to Seg  2 of Loc. 0.   (See also locations 4, 8, 12, 16, 20, 24, 28) 

Location 69 

Authorizing Users 11-20 

 

Segment 1 corresponds to user 11; Segment 10 corresponds to user 20.  

Location 70 

Authorizing Users 21-30 

 

Segment 1 corresponds to user 21; Segment 10 corresponds to user 30.   

Location 71 

Authorizing Users 31-40 

 

Segment 1 corresponds to user 31; Segment 10 corresponds to user 40.   

Location 72 

Authorizing Users 41-50  

 

Segment 1 corresponds to user 41; Segment 10 corresponds to user 50. 

Location 73 

Authorizing Users 51-60  

Segment 1 corresponds to user 51; Segment 10 corresponds to user 60.  

Содержание NX-507E

Страница 1: ...NetworX Series NX 507E RELAY EXPANDER NX 508E OUTPUT EXPANDER Installation and Startup...

Страница 2: ......

Страница 3: ...ERMINAL DESCRIPTION 5 IV NX 507E DRAWING 6 V NX 508E TERMINAL DESCRIPTION 7 VI NX 508E DRAWING 7 VII INSTALLING THE MODULES 8 VIII ENROLLING THE MODULES 8 IX PROGRAMMING THE MODULES 8 X PROGRAMMING LO...

Страница 4: ...inal see terminal descriptions making it ideal for use in a remote location NX 508E EIGHT OUTPUT EXPANDER Microprocessor controlled 8 output module Equipped with 8 low current trigger outputs see term...

Страница 5: ...rate from the power in the control panel AUX Any power drain from this terminal should be included in total current draw from the NetworX control panel or NX 320E Power Supply as applicable This allow...

Страница 6: ...6 NX 507E NX 508E AUXILIARY MODULES IV NX 507E DRAWING All outputs are Class 2 power limited...

Страница 7: ...om the power in the control panel AUX Any power drain from this terminal should be included in total current draw from the NetworX control panel or NX 320E as applicable This allows an isolation of th...

Страница 8: ...to program should be entered Next enter the address of the NX 508E you wish to program followed by refer to Table VII 1 on page 8 At this point the Armed LED will illuminate while it is waiting for a...

Страница 9: ...m Disarm Control 11 Duress 31 Closed Schedule 51 Follow schedule of NX 508E 12 Manual Fire 32 Listen In 52 Flash X 10 for Alarm Memory 13 Aux 2 Keypad 33 Line Seizure 53 Flash X 10 for Siren 14 Keypad...

Страница 10: ...ule 3 LED 4 On if the event should follow Schedule 4 LED 5 On if the event should follow Schedule 5 LED 6 On if the event should follow Schedule 6 LED 7 On if the event should follow Schedule 7 LED 8...

Страница 11: ...to a maximum of 8 holidays per location month Locations 57 67 Programming the Date of Holidays from February to December 8 segments of numerical data Locations 57 67 are used to program the day of eac...

Страница 12: ...g Users 161 170 egment 1 corresponds to user 161 Segment 10 corresponds to user 170 Location 85 Authorizing Users 171 180 Segment 1 corresponds to user 171 Segment 10 corresponds to user 180 Location...

Страница 13: ...e C and Unit Code 4 for 6 minutes when Zone 1 is faulted only from 5 00 p m to 9 00 a m program the following SEGMENT LOC 1 2 3 0 42 1 6 1 LED 1 2 3 4 5 6 7 8 2 1 2 3 4 5 6 7 8 3 3 2 32 9 0 33 17 0 34...

Страница 14: ...ition 7 8 Partition 8 Output 1 Schedule 2 10 1 Schedule 1 2 Schedule 2 3 Schedule 3 4 Schedule 4 5 Schedule 5 6 Schedule 6 7 Schedule 7 8 Schedule 8 3 Output 1 X 10 Address Segment 1 Module Number 0 1...

Страница 15: ...until a code is entered 3 Partition 3 3 On if output should reset if a code is entered while it is being timed 4 Partition 4 5 Partition 5 4 On if output should only trigger during a closed schedule...

Страница 16: ...2 House Code See chart on page 14 0 16 10 Output 5 Event Zone Time _ _ _ 43 5 10 Output 5 Special Functions Partition Segment 1 Segment 2 17 10 1 On if output should time in minutes Off if output tim...

Страница 17: ...1 Module Number 5 23 10 Segment 2 House Code See chart on page 14 0 24 10 Output 7 Event Zone Time _ _ _ 43 7 10 Output 7 Special Functions Partition Segment 1 Segment 2 25 10 1 On if output should ti...

Страница 18: ...should be logged in event buffer Output 8 Schedule 30 10 1 Schedule 1 5 Schedule 5 2 Schedule 2 6 Schedule 6 3 Schedule 3 7 Schedule 7 4 Schedule 4 8 Schedule 8 Output 8 X 10 Address Segment 1 Module...

Страница 19: ...3 Tuesday 7 Saturday 4 Wednesday 8 Disabled on holidays 50 11 Schedule 7 Opening Time 8 0 51 11 Schedule 7 Closing Time 20 0 Schedule 7 Days 52 11 5 Thursday 1 Sunday 2 Monday 6 Friday 3 Tuesday 7 Sat...

Страница 20: ...ut 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2...

Страница 21: ...put 5 Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CODES 7...

Страница 22: ...Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 80 12 CODES...

Страница 23: ...Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 85 12 CODES...

Страница 24: ...218 219 220 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2...

Страница 25: ...hole is for the screw Diagram 2 Place the first black plastic PCB guide in the top insertion point grooved edge downward The half moon protrusion will be in the large hole It does not require force In...

Страница 26: ...degrees F SHIPPING WEIGHT 1 lb COMPATIBLE NETWORX CONTROL PANELS NX 4 NX 6 NX 8 NX 8E NX 4V2 NX 6V2 NX 8V2 UNDERWRITERS LABORATORIES LISTINGS UL365 Police Station Connected Burglar Alarm Units System...

Отзывы: