Location 33
Programming the Closing Time for Schedule 1
(2 segments of numerical data)
Segment 1
Program the hour of the closing time in 24-hour format. (1:00 PM = 13)
Segment 2
Program the minutes after the hour of the closing time for Schedule 1.
Location 34
Programming the Days for Schedule 1
(1 segment of numerical data)
LED DESCRIPTION
1
"On" if the schedule is active on Sunday.
2
"On" if the schedule is active on Monday.
3
"On" if the schedule is active on Tuesday.
4 “
On" if the schedule is active on Wednesday.
5
"On" if the schedule is active on Thursday.
6
"On" if the schedule is active on Friday.
7
“On" if the schedule is active on Saturday.
8
"On" if the schedule is disabled on holidays.
Locations 35 - 55 Programming for Schedules 2-8
(2 segments of numerical data) Locations 35 - 55 are used to program the opening times, closing times, and
days for Schedules 2 - 8. Each schedule has three locations that are programmed with the same steps as
Schedule 1 described previously. Refer to Schedule 1 (locations 32 - 34 above) for specific instructions and the
worksheets beginning on page 14.
Location 56
Programming the Date of Holidays in January
(8 segments of numerical data) Program the day of the month in January that the Opening time in a schedule is
suppressed. For example, if the opening should not occur on January 1, program a "1" in Segment 1. This
feature can be repeated up to a maximum of 8 holidays per location (month).
Locations 57-67 Programming the Date of Holidays from February to December
(8 segments of numerical data) Locations 57 - 67 are used to program the day of each month, from February to
December, in which the Opening time in a schedule is suppressed. Each location will accommodate up to a
maximum of 8 holidays, and programmed with the same steps as Location 56 described previously. Refer to
worksheets.
Locations 68-91 Authorizing Users for Outputs 1-8
(10 segments of binary data) When activating outputs with a user code (event #45), locations 68-91 can be used
to restrict certain codes from activating certain outputs. At factory default, all users have full authorization.
Each location contains 10 segments. The LEDs correspond to outputs 1 - 8. Refer to Table X-1 on page 12
Location 68
Authorizing Users 1-10
Segment 1 corresponds to user 1; Segment 10 corresponds to user 10.
NOTE
: To use locations 68-91, a “0” must be programmed in segment 2 (zone/user) of the
corresponding output. Refer to Seg 2 of Loc. 0. (See also locations 4, 8, 12, 16, 20, 24, 28)
Location 69
Authorizing Users 11-20
Segment 1 corresponds to user 11; Segment 10 corresponds to user 20.
Location 70
Authorizing Users 21-30
Segment 1 corresponds to user 21; Segment 10 corresponds to user 30.
Location 71
Authorizing Users 31-40
Segment 1 corresponds to user 31; Segment 10 corresponds to user 40.
Location 72
Authorizing Users 41-50
Segment 1 corresponds to user 41; Segment 10 corresponds to user 50.
Location 73
Authorizing Users 51-60
Segment 1 corresponds to user 51; Segment 10 corresponds to user 60.