NX-507E / NX-508E AUXILIARY MODULES

  

  

  

 

 

VII. 

INSTALLING THE MODULES 

The first thing that must be decided is the address of this particular relay/output module. This is the address that 

will be selected when programming the auxiliary devices. To set the addresses use the table below.   

"

 

DipSwitch 4 is used to disable the Tamper feature.  ("On" = enabled / "Off" = disabled)

 

Table VII-1 

 

Address 

 

Dip Switch 1 

 

Dip Switch 2 

 

Dip Switch 3 

24 ON ON OFF 
25 OFF OFF ON 
26  ON OFF ON 
27 OFF ON ON 
28  ON ON ON 
29  OFF OFF OFF 
30 ON OFF OFF 
31  OFF ON OFF

 

 

VIII. 

ENROLLING THE MODULES 

The NetworX control panels have the ability to automatically find and store in memory the presence of all 

keypads, zone expanders, wireless receivers, output modules, and any other device on the keypad buss.  This 

allows these devices to be supervised by the control panel.  To enroll the devices, enter the Program Mode using 

the procedure outlined in the control panel Installation Manual.  When the Program Mode is exited, the NX 

control panel will automatically enroll the devices.  The enrolling process takes about 12 seconds, during which 

time the “Service” LED will illuminate.  User codes will not be accepted during the enrolling process.  Once a 

module is enrolled, if it is not detected by the control, the “Service” LED will illuminate. 

 

IX. 

PROGRAMMING THE MODULES 

The Program Mode is accessed by entering [

Á

]-[

8

]  (all of the function key LEDs will begin to flash).  Enter the "Go 

To Program" code (default is [

9

]-[

7

]-[

1

]-[

3

]).  If the code was valid, the Service LED will flash, and the function 

LEDs will illuminate steady, indicating the device to program should be entered.  Next, enter the address of the 
NX-508E you wish to program followed by [

#

] (

refer to Table VII-1 on page 8)

. At this point, the Armed LED will 

illuminate while it is waiting for a programming location to be entered.  Enter the desired programming location. 
 The Armed LED will begin to flash while a programming location is being entered.  Enter [

#

].  If this is a valid 

location, the Armed LED will extinguish, the Ready LED will illuminate, and the binary data for the first segment of 

this location will be shown on the zone LEDS.  To change the data, enter the data followed by [

Á

].  The data will 

be entered, and the location will automatically increment to the next segment.  The data for that segment will be 
displayed.  This procedure is repeated until the last segment is reached.  Pressing  [

#

] will exit from this location. 

To review the data, repeat the above procedure and press [

Á

] without entering data first. Each time [

Á

] is 

pressed the next segment is displayed.  Programming data is always one of two types of data. The first type is 

numerical, and can take on values from 0-255 or 0-15 depending on the segment size.  The second type is a 
feature selection type.  Feature selection data is used to turn features on or off. 

LCD Keypad Users Note:

 All 

steps required for programming are the same as the aforementioned LED keypad.  The LCD keypad display will 

prompt you for the data required.  While in the programming mode, and not in a location, the number in 

parenthesis is the location you were previously changing.  For example, if the display reads "Enter location, then 

#   (5)", it is reminding you that location 5 was the last location you programmed.  In feature selection data, the 
numbers of the enabled features will be displayed. The features 

not

 enabled will display a hyphen (-). 

Содержание NX-507E

Страница 1: ...NetworX Series NX 507E RELAY EXPANDER NX 508E OUTPUT EXPANDER Installation and Startup...

Страница 2: ......

Страница 3: ...ERMINAL DESCRIPTION 5 IV NX 507E DRAWING 6 V NX 508E TERMINAL DESCRIPTION 7 VI NX 508E DRAWING 7 VII INSTALLING THE MODULES 8 VIII ENROLLING THE MODULES 8 IX PROGRAMMING THE MODULES 8 X PROGRAMMING LO...

Страница 4: ...inal see terminal descriptions making it ideal for use in a remote location NX 508E EIGHT OUTPUT EXPANDER Microprocessor controlled 8 output module Equipped with 8 low current trigger outputs see term...

Страница 5: ...rate from the power in the control panel AUX Any power drain from this terminal should be included in total current draw from the NetworX control panel or NX 320E Power Supply as applicable This allow...

Страница 6: ...6 NX 507E NX 508E AUXILIARY MODULES IV NX 507E DRAWING All outputs are Class 2 power limited...

Страница 7: ...om the power in the control panel AUX Any power drain from this terminal should be included in total current draw from the NetworX control panel or NX 320E as applicable This allows an isolation of th...

Страница 8: ...to program should be entered Next enter the address of the NX 508E you wish to program followed by refer to Table VII 1 on page 8 At this point the Armed LED will illuminate while it is waiting for a...

Страница 9: ...m Disarm Control 11 Duress 31 Closed Schedule 51 Follow schedule of NX 508E 12 Manual Fire 32 Listen In 52 Flash X 10 for Alarm Memory 13 Aux 2 Keypad 33 Line Seizure 53 Flash X 10 for Siren 14 Keypad...

Страница 10: ...ule 3 LED 4 On if the event should follow Schedule 4 LED 5 On if the event should follow Schedule 5 LED 6 On if the event should follow Schedule 6 LED 7 On if the event should follow Schedule 7 LED 8...

Страница 11: ...to a maximum of 8 holidays per location month Locations 57 67 Programming the Date of Holidays from February to December 8 segments of numerical data Locations 57 67 are used to program the day of eac...

Страница 12: ...g Users 161 170 egment 1 corresponds to user 161 Segment 10 corresponds to user 170 Location 85 Authorizing Users 171 180 Segment 1 corresponds to user 171 Segment 10 corresponds to user 180 Location...

Страница 13: ...e C and Unit Code 4 for 6 minutes when Zone 1 is faulted only from 5 00 p m to 9 00 a m program the following SEGMENT LOC 1 2 3 0 42 1 6 1 LED 1 2 3 4 5 6 7 8 2 1 2 3 4 5 6 7 8 3 3 2 32 9 0 33 17 0 34...

Страница 14: ...ition 7 8 Partition 8 Output 1 Schedule 2 10 1 Schedule 1 2 Schedule 2 3 Schedule 3 4 Schedule 4 5 Schedule 5 6 Schedule 6 7 Schedule 7 8 Schedule 8 3 Output 1 X 10 Address Segment 1 Module Number 0 1...

Страница 15: ...until a code is entered 3 Partition 3 3 On if output should reset if a code is entered while it is being timed 4 Partition 4 5 Partition 5 4 On if output should only trigger during a closed schedule...

Страница 16: ...2 House Code See chart on page 14 0 16 10 Output 5 Event Zone Time _ _ _ 43 5 10 Output 5 Special Functions Partition Segment 1 Segment 2 17 10 1 On if output should time in minutes Off if output tim...

Страница 17: ...1 Module Number 5 23 10 Segment 2 House Code See chart on page 14 0 24 10 Output 7 Event Zone Time _ _ _ 43 7 10 Output 7 Special Functions Partition Segment 1 Segment 2 25 10 1 On if output should ti...

Страница 18: ...should be logged in event buffer Output 8 Schedule 30 10 1 Schedule 1 5 Schedule 5 2 Schedule 2 6 Schedule 6 3 Schedule 3 7 Schedule 7 4 Schedule 4 8 Schedule 8 Output 8 X 10 Address Segment 1 Module...

Страница 19: ...3 Tuesday 7 Saturday 4 Wednesday 8 Disabled on holidays 50 11 Schedule 7 Opening Time 8 0 51 11 Schedule 7 Closing Time 20 0 Schedule 7 Days 52 11 5 Thursday 1 Sunday 2 Monday 6 Friday 3 Tuesday 7 Sat...

Страница 20: ...ut 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2...

Страница 21: ...put 5 Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CODES 7...

Страница 22: ...Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 80 12 CODES...

Страница 23: ...Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 85 12 CODES...

Страница 24: ...218 219 220 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2...

Страница 25: ...hole is for the screw Diagram 2 Place the first black plastic PCB guide in the top insertion point grooved edge downward The half moon protrusion will be in the large hole It does not require force In...

Страница 26: ...degrees F SHIPPING WEIGHT 1 lb COMPATIBLE NETWORX CONTROL PANELS NX 4 NX 6 NX 8 NX 8E NX 4V2 NX 6V2 NX 8V2 UNDERWRITERS LABORATORIES LISTINGS UL365 Police Station Connected Burglar Alarm Units System...

Отзывы: