background image

12    

NX-507E / NX-508E AUXILIARY MODULES 

 

Location 74 

Authorizing Users 61-70 

Segment 1 corresponds to user 61; Segment 10 corresponds to user 70.  

Location 75 

Authorizing Users 71-80  

Segment 1 corresponds to user 71; Segment 10 corresponds to user 80.  

Location 76 

Authorizing Users 81-90  

Segment 1 corresponds to user 81; Segment 10 corresponds to user 90.  

Location 77 

Authorizing Users 91-100 

Segment 1 corresponds to user 91; Segment 9 corresponds to user 100.   

Location 78 

Authorizing Users 101-110  

Segment 1 corresponds to user 101; Segment 10 corresponds to user 110.   

Location 79 

Authorizing Users 111-120  

Segment 1 corresponds to user 111; Segment 10 corresponds to user 120.   

Location 80 

Authorizing Users 121-130 

Segment 1 corresponds to user 121; Segment 10 corresponds to user 130.   

Location 81 

Authorizing Users 131-140  

Segment 1 corresponds to user 131; Segment 10 corresponds to user 140.   

Location 82 

Authorizing Users 141-150 

Segment 1 corresponds to user 141; Segment 10 corresponds to user 150.   

Location 83 

Authorizing Users 151-160  

Segment 1 corresponds to user 151; Segment 10 corresponds to user 160.   

Location 84 

Authorizing Users 161-170 

egment 1 corresponds to user 161; Segment 10 corresponds to user 170.   

Location 85 

Authorizing Users 171-180 

Segment 1 corresponds to user 171; Segment 10 corresponds to user 180.  

Location 86 

Authorizing Users 181-190  

 

Segment 1 corresponds to user 181; Segment 10 corresponds to user 190.   

Location 87 

Authorizing Users 191-200 

 

Segment 1 corresponds to user 191; Segment 10 corresponds to user 200.  

Location 88 

Authorizing Users 201-210  

 

Segment 1 corresponds to user 201; Segment 10 corresponds to user 210.   

Location 89 

Authorizing Users 211-220  

 

Segment 1 corresponds to user 211; Segment 10 corresponds to user 220.   

Location 90 

Authorizing Users 221-230  

 

Segment 1 corresponds to user 221; Segment 10 corresponds to user 230.  

Location 91 

Authorizing Users 231-240 for Outputs 1-8 

 

Segment 1 corresponds to user 231; Segment 10 corresponds to user 240.   

 

Table X-1 

LED DESCRIPTION 

"On" if code will activate Output 1; "Off" if it will not. 

"On" if code will activate Output 2; "Off" if it will not. 

"On" if code will activate Output 3; "Off" if it will not. 

"On" if code will activate Output 4; "Off" if it will not. 

"On" if code will activate Output 5; "Off" if it will not. 

"On" if code will activate Output 6; "Off" if it will not. 

"On" if code will activate Output 7; "Off" if it will not. 

"On" if code will activate Output 8; "Off" if it will not. 

 

 

Содержание NX-507E

Страница 1: ...NetworX Series NX 507E RELAY EXPANDER NX 508E OUTPUT EXPANDER Installation and Startup...

Страница 2: ......

Страница 3: ...ERMINAL DESCRIPTION 5 IV NX 507E DRAWING 6 V NX 508E TERMINAL DESCRIPTION 7 VI NX 508E DRAWING 7 VII INSTALLING THE MODULES 8 VIII ENROLLING THE MODULES 8 IX PROGRAMMING THE MODULES 8 X PROGRAMMING LO...

Страница 4: ...inal see terminal descriptions making it ideal for use in a remote location NX 508E EIGHT OUTPUT EXPANDER Microprocessor controlled 8 output module Equipped with 8 low current trigger outputs see term...

Страница 5: ...rate from the power in the control panel AUX Any power drain from this terminal should be included in total current draw from the NetworX control panel or NX 320E Power Supply as applicable This allow...

Страница 6: ...6 NX 507E NX 508E AUXILIARY MODULES IV NX 507E DRAWING All outputs are Class 2 power limited...

Страница 7: ...om the power in the control panel AUX Any power drain from this terminal should be included in total current draw from the NetworX control panel or NX 320E as applicable This allows an isolation of th...

Страница 8: ...to program should be entered Next enter the address of the NX 508E you wish to program followed by refer to Table VII 1 on page 8 At this point the Armed LED will illuminate while it is waiting for a...

Страница 9: ...m Disarm Control 11 Duress 31 Closed Schedule 51 Follow schedule of NX 508E 12 Manual Fire 32 Listen In 52 Flash X 10 for Alarm Memory 13 Aux 2 Keypad 33 Line Seizure 53 Flash X 10 for Siren 14 Keypad...

Страница 10: ...ule 3 LED 4 On if the event should follow Schedule 4 LED 5 On if the event should follow Schedule 5 LED 6 On if the event should follow Schedule 6 LED 7 On if the event should follow Schedule 7 LED 8...

Страница 11: ...to a maximum of 8 holidays per location month Locations 57 67 Programming the Date of Holidays from February to December 8 segments of numerical data Locations 57 67 are used to program the day of eac...

Страница 12: ...g Users 161 170 egment 1 corresponds to user 161 Segment 10 corresponds to user 170 Location 85 Authorizing Users 171 180 Segment 1 corresponds to user 171 Segment 10 corresponds to user 180 Location...

Страница 13: ...e C and Unit Code 4 for 6 minutes when Zone 1 is faulted only from 5 00 p m to 9 00 a m program the following SEGMENT LOC 1 2 3 0 42 1 6 1 LED 1 2 3 4 5 6 7 8 2 1 2 3 4 5 6 7 8 3 3 2 32 9 0 33 17 0 34...

Страница 14: ...ition 7 8 Partition 8 Output 1 Schedule 2 10 1 Schedule 1 2 Schedule 2 3 Schedule 3 4 Schedule 4 5 Schedule 5 6 Schedule 6 7 Schedule 7 8 Schedule 8 3 Output 1 X 10 Address Segment 1 Module Number 0 1...

Страница 15: ...until a code is entered 3 Partition 3 3 On if output should reset if a code is entered while it is being timed 4 Partition 4 5 Partition 5 4 On if output should only trigger during a closed schedule...

Страница 16: ...2 House Code See chart on page 14 0 16 10 Output 5 Event Zone Time _ _ _ 43 5 10 Output 5 Special Functions Partition Segment 1 Segment 2 17 10 1 On if output should time in minutes Off if output tim...

Страница 17: ...1 Module Number 5 23 10 Segment 2 House Code See chart on page 14 0 24 10 Output 7 Event Zone Time _ _ _ 43 7 10 Output 7 Special Functions Partition Segment 1 Segment 2 25 10 1 On if output should ti...

Страница 18: ...should be logged in event buffer Output 8 Schedule 30 10 1 Schedule 1 5 Schedule 5 2 Schedule 2 6 Schedule 6 3 Schedule 3 7 Schedule 7 4 Schedule 4 8 Schedule 8 Output 8 X 10 Address Segment 1 Module...

Страница 19: ...3 Tuesday 7 Saturday 4 Wednesday 8 Disabled on holidays 50 11 Schedule 7 Opening Time 8 0 51 11 Schedule 7 Closing Time 20 0 Schedule 7 Days 52 11 5 Thursday 1 Sunday 2 Monday 6 Friday 3 Tuesday 7 Sat...

Страница 20: ...ut 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2...

Страница 21: ...put 5 Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CODES 7...

Страница 22: ...Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 80 12 CODES...

Страница 23: ...Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 85 12 CODES...

Страница 24: ...218 219 220 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2...

Страница 25: ...hole is for the screw Diagram 2 Place the first black plastic PCB guide in the top insertion point grooved edge downward The half moon protrusion will be in the large hole It does not require force In...

Страница 26: ...degrees F SHIPPING WEIGHT 1 lb COMPATIBLE NETWORX CONTROL PANELS NX 4 NX 6 NX 8 NX 8E NX 4V2 NX 6V2 NX 8V2 UNDERWRITERS LABORATORIES LISTINGS UL365 Police Station Connected Burglar Alarm Units System...

Отзывы: