Network Technologies XTENDEX ST-C5V-600 Скачать руководство пользователя страница 9

6

Plug-in and Boot Up

1.  Plug the power cord from each monitor into a power outlet.

2. 

Connect the power connector from the AC adapter to the 9VDC port on the Remote Unit.   Make sure the
power connector goes into the port all the way.    Plug the AC adapter into a power outlet.   The yellow LED
on the RJ45 connector on the Remote and Local Units should illuminate, indicating that a proper power
connection has been made to both.    (See Fig. 4.)

Note:  The Local Unit is powered by the Remote Unit.

                                  Figure 4- Connect the AC adapter to the Remote Unit

3.  Turn ON the CPU and monitors.    They should each react as if they were directly connected to each other.

Video Quality

Adjust the Video Quality

 

It is possible that on initial startup the image on the monitor will not be as crisp as the image normally is. This is

due to the frequency characteristics of the CAT5 cable.    It may be necessary to press the "+"  or  "-" buttons
(see Fig. 5) until the image is crisp and clear.   Press the "+" button if the image is not crisp and clear enough.
Press the "-" button if the image has been over-corrected (such that horizontal lines appear to trail or shadow at
the edge of an open window).   A momentary press of either button will make a minor change in the image.   If
either button is pressed and held, the changes made will be gradual and continuous.   Ultimately, the image
quality should improve to a satisfactory level.   Once the adjustment is made, it should not be necessary to
change it again as the new settings are stored in memory and become the default settings with each startup.

Video Quality

Plug-in and Boot Up

9   V D C

A d a p t e r

A D A P T E R

B a r r e l

( I n s i d e

b a r r e l )

( O u t s i d e

b a r r e l )

P o w e r   C o n n e c t o r

2 . 1   m m   x   5 . 5   m m   F e m a l e

9 V D C   @   1 . 5 A   O U T P U T

Y e l l o w   P o w e r   L E D

R e a r   V i e w   o f   R e m o t e   U n i t

Содержание XTENDEX ST-C5V-600

Страница 1: ...0 VIDEO EXTENDER Installation and Operation Manual Manual 072 Rev 3 10 03 XTENDEXTM Series NTI NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora OH 44202 www nt...

Страница 2: ...rved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior w...

Страница 3: ...Technical Specifications 7 Interconnection Cable Wiring Method 7 Troubleshooting 8 Table of Figures Figure 1 Connect the Local Unit to the CPU 4 Figure 2 Connect Local User s Monitor to Local Unit 4...

Страница 4: ...h XGA VGA and SVGA systems Provides crisp and clear resolution up to 1280 x 1024 600 feet Compatible with all NTI video switches and splitters enabling the joining of products to create a system that...

Страница 5: ...nector blue 15HD male for connecting to the video port on the CPU or NTI switch 6 Video Connector 15HD female for connecting the remote user s monitor 7 and buttons for manual adjustment of video qual...

Страница 6: ...reach from the wall outlets to the connection locations of the Remote and Local Units A properly grounded polarized and preferably surge protected 120V or 240V electrical outlet depending on the AC a...

Страница 7: ...45 wall outlet WARNING Never connect the ST C5V 600 Extender to an ethernet card ethernet router hub or switch or other ethernet RJ45 connector of an ethernet device Damage to devices connected to the...

Страница 8: ...the Remote Unit See Fig 3 When properly inserted the CAT5 cable end should snap into place Note If an RJ45 wall outlet is being used connect the other end of the extension cable to the RJ45 wall outl...

Страница 9: ...equency characteristics of the CAT5 cable It may be necessary to press the or buttons see Fig 5 until the image is crisp and clear Press the button if the image is not crisp and clear enough Press the...

Страница 10: ...connectors Remote Unit Power 120V or 240V at 50 or 60Hz 9VDC 1 5A via AC Adapter Local Unit Power Powered by Remote Unit Dimensions 3 1 W x 3 4 D x 1 H Interconnection Cable Wiring Method The connect...