background image

1

Introduction

The NTI ST-nXm-U-HD  (also known as NODEMUX-HD) is a multi-user / Universal Multi-Platform Matrix KVM switch, (n= number
of users, m= number of CPUs) with high density construction to require less rack space.  It allows multiple users, up to 4, each with
a keyboard, monitor, and mouse, to communicate directly with any PS/2 or SUN workstation connected to the switch.  A single
switch can connect to 16 CPUs or up to 256 CPUs when switches are cascaded.  These CPUs can be file servers, network
managers, etc.  The auto-boot circuitry in the NTI switch allows all CPUs to boot simultaneously without keyboard and/or mouse
error.

Definitions

 CPU

Enclosure that contains the operating system and processor

 User 

Device

Keyboard or Mouse

 System

One or more CPUs connected to one or more switches controlled by one or more user devices

 OSD

On Screen Display

Limitations

 Only 

VGA multi-scan Monitors

 can be used with this product.

Compatibility

The ST-nXm-U-HD Universal Matrix KVM switch supports the following:

 

Windows PS/2 CPUs

 

SUN CPUs (including all SUN Ultras, SUN Blades and SUN Rays)  (USB SUN CPU's need USB-SUN adapter)

 PS/2 

laptops

Ordering Information

The ST-nXm-U-HD switch is built to a specific size ranging from 2 to 4 users and 8 to 16 CPUs.  The switch is built at the factory
based on the specified size ordered.  The switch has high density connectors (similar to SCSI) for inputs and outputs that support
PS/2  and SUN platforms and are configured with interface cables, see interface cable section.  The “n” in the part number ST-
nXm-U-HD represents the number of users. Select either 2 or 4 user switches.  The “m” in the part number represents the number
of CPUs.  The switch is available with either 8 or 16 CPU ports.  It is not necessary to connect a user or CPU to each port (ex.  a
ST-2x16 switch has the capability of supporting 16 CPUs, but can have only 10 CPUs connected and 6 empty ports.

ST-nXm-U-HD
Replace the “n” with either 2 or 4
Replace the “m” with either 8 or 16

  The following list represents the available sizes that can be ordered:

ST-2x8-U-HD

ST-4X8-U-HD

ST-2x16-U-HD

ST-4X16-U-HD

Options

The following options are available for the ST-nXm-U-HD switch.

Dual Redundant Power supply

This feature ensures constant power to the unit.
Ordered by adding a -DRP suffix to the main part number.

Ordering Information

Compatibility

Introduction

Содержание NODEMUX HD Series

Страница 1: ...ti user Universal KVM Switch INSTALLATION USER GUIDE MAN001 Rev Date 1 6 2003 NTI NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora OH 44202 www nti1 com R NODE...

Страница 2: ...ight 2003 by Network Technologies Inc All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical ph...

Страница 3: ...curity Feature 7 User Login Mode 8 Additional OSD Modes Available With Security 8 Administration Functions 8 Administration Options 8 Port Status Mode 9 Administrator Password 9 User Name List 10 Syst...

Страница 4: ...e 2 Connect CPUs to switch using interface cables 5 Figure 3 User login screen 7 Figure 4 Administration Mode Menu 9 Figure 5 Administrator password menu 9 Figure 6 User Name List 10 Figure 7 Command...

Страница 5: ...SUN Rays USB SUN CPU s need USB SUN adapter PS 2 laptops Ordering Information The ST nXm U HD switch is built to a specific size ranging from 2 to 4 users and 8 to 16 CPUs The switch is built at the...

Страница 6: ...res and Functions 1 Keypad buttons for user control over switch functions 2 LCD Display for visual indication of connection between the user and a specific CPU 3 Power ON OFF switch 4 Fuse Holder hold...

Страница 7: ...PU preventing connected CPUs from locking up Each connected CPU can boot without a keyboard or mouse Keyboard and mouse interface cable can be hot plugged during operation LCD display on the front pan...

Страница 8: ...cable to the devices port s and video port of the CPU as shown in Fig 2 NOTE If the CPU is a SUN type with 13W3 video connector use an NTI 13W3M 15HDF adapter to connect the SMTINT xx MM cable to the...

Страница 9: ...m D M a l e P u r p l e K e y b o a r d V M T I N T 3 6 1 0 1 5 2 5 M M H D 1 5 M a l e D k B l u e T o 8 m i n i D I N f e m a l e d e v i c e s p o r t o n S U N C P U R E A R V I E W O F P S 2 C P...

Страница 10: ...digit user entries ENTER Used following single digit entries Display next 4 users and the CPUs they are connected to See note below Display previous 4 users and the CPUs they are connected to See not...

Страница 11: ...e from the keyboard using the Ctrl accent key The OSD menu will automatically appear on the monitor This provides a visual way to control the ST nXm U HD switch using the keyboard and mouse The admini...

Страница 12: ...r Port Status mode for selected port Exit Administration and Return to previous mode Administration Options To enter the Administration Options mode press A from the Maintenance Mode menu See page 14...

Страница 13: ...c Administrator Password To enter the Administrator Password menu press C from the Administration Mode menu The Administrator Password menu see Fig 5 enables the administrator to change his password T...

Страница 14: ...hlighted user s password Return to Administration Mode Figure 6 User Name List System Access List To enter the System Access List press Ctrl A from the User Name List The System access list displays t...

Страница 15: ...eft of a port number in the list indicates the port the user is currently connected to From left to right the columns display the following Port Number Port Name Type of CPU connected Power Status of...

Страница 16: ...n with the mouse Scan Mode To activate Scan Mode press Ctrl S from the Command Mode menu Scan Mode enables the user to scan through selected ports and to have full device control of the connected port...

Страница 17: ...us character When finished making changes in Edit Mode press Esc and a prompt will appear to press either Y to save the changes or N to continue making changes without saving the changes just made Sea...

Страница 18: ...ic listing of ports Move On Screen Display OSD menu up on monitor Move OSD menu down on monitor Move OSD menu to the right Move OSD menu to the left Make OSD menu taller Make OSD menu shorter Figure 8...

Страница 19: ...nformation on any command Function Keystroke View the previous page of help if available View the next page of help if available Exit HELP and return to previous mode Keyboards The keyboard configurat...

Страница 20: ...FT Arrow Mute SB Space Bar Figure 9 Keyboard Layouts E n t e r E n t e r C t r l S h i f t S h i f t C a p s L o c k T a b E s c C t r l A l t B a c k s p a c e N u m L o c k E n t e r E n t e r A l t...

Страница 21: ...ed data protocol of 8 data bits no parity and 1 stop bit The baud rate is selectable through the Baud Rate Menu A data protocol of 8 data bits no parity and 1 stop bit is used in the daisy chain commu...

Страница 22: ...T along with the Matrix Switcher s Control Program see page 18 is installed from the 3 1 4 floppy disc packaged with this switch SERTEST generates a main menu with the 3 selections described below Mai...

Страница 23: ...and for all switches h Restore All Units I O Connections from Units Memory restore the connections from switch memory bank command for all switches i Change All Units Baud Rate 9600 COM1 change RS 232...

Страница 24: ...TART 2 Click on PROGRAMS 3 Click on NTI 4 Click on MSCP Help Dual Redundant Power Supply The ST nXm U HD switch may be purchased with an optional Dual Redundant Power supply This feature allows an ext...

Страница 25: ...fety and EMC Regulatory Statements WARNING A WARNING in this manual indicates the potential for serious injury or death CAUTION A CAUTION in this manual indicates the potential for damage to the equip...

Страница 26: ...0 562 7070 Appendix D Rack mounting Instructions If this NTI switch was designed to be directly mounted to a rack it includes a mounting flange to make attachment easy Install 4 captive nuts to the ra...

Страница 27: ...23 SERIAL NO DATE INSPECTED BY ST 2x8 U HD ST 4x8 U HD ST 4x8 U HD ST 4x16 U HD OPTION Dual Redundant Power Supply...

Отзывы: