Potential Device Customizing

Depends on which two model of Z801TXB purchased. It comes with either 3 or 5 sensor
connection ports. To specify ZigBee zone type given in HA Profile for your needs, at your
next purchase order Netvox offers to re-write the zone type for each of these ports. Write
to us and list out which S port to be which of the 12 available HA Profile zone types in the
table bellow. Note that if you have only 3 ports then you are only to have 3 zone types.
One zone type per each port. Same thing goes to 5 ports Z801TXB.

0x00: EMBER_ZCL_IAS_ZONE_TYPE_STANDARD_CIE = 0x0000,
0x01: EMBER_ZCL_IAS_ZONE_TYPE_MOTION_SENSOR = 0x000D,
0x02: EMBER_ZCL_IAS_ZONE_TYPE_CONTACT_SWITCH = 0x0015,
0x03: EMBER_ZCL_IAS_ZONE_TYPE_FIRE_SENSOR = 0x0028,
0x04: EMBER_ZCL_IAS_ZONE_TYPE_WATER_SENSOR = 0x002A,
0x05: EMBER_ZCL_IAS_ZONE_TYPE_GAS_SENSOR = 0x002B,
0x06: EMBER_ZCL_IAS_ZONE_TYPE_PERSONAL_EMERGENCY_DEVICE = 0x002C,
0x07: EMBER_ZCL_IAS_ZONE_TYPE_VIBRATION_MOVEMENT_SENSOR = 0x002D,
0x08: EMBER_ZCL_IAS_ZONE_TYPE_REMOTE_CONTROL = 0x010F,
0x09: EMBER_ZCL_IAS_ZONE_TYPE_KEY_FOB = 0x0115,
0x0A: EMBER_ZCL_IAS_ZONE_TYPE_KEYPAD = 0x021D,
0x0B: EMBER_ZCL_IAS_ZONE_TYPE_STANDARD_WARNING_DEVICE = 0x0225

By default, all the ports are shipped as
0x02: EMBER_ZCL_IAS_ZONE_TYPE_CONTACT_SWITCH = 0x0015

Содержание Z801TXB

Страница 1: ...ZigBeeTM Pulse Signal Detector User Manual Pulse Signal Detector Model Z801TXB Compatible with ZigBee Home Automation Profile 201040210 FW V3 1 HW V4 3 V4 4 ...

Страница 2: ...Model Z801TXB Signal 1 Signal 2 Signal 3 Signal 4 Signal 5 Back View Status LED1 Network LED2 GND Binding Key Battery Compartment ...

Страница 3: ...in between wireless markup technology and Bluetooth ZigBee is based on IEEE802 15 4 standard the mutual co ordination between thousands of sensors to exchange data Sensor to sensor or node to node communication is achieved through relays of control data between devices with only a fraction of energy use which denoted for highly transmission efficiency Note Wireless communication in some real use c...

Страница 4: ...ion operation Step 1 Make sure you have opened up permit join function valid for 60 seconds of a coordinator or a router Step 2 Give power to Z801TXB device refer to How to power up the device The device will start to search for the network within reach Step 3 The network status indicator on the Z801TXB will flash 5 times when it finds the network otherwise the indicator stays unchanged If it fail...

Страница 5: ...01TXB to a preferred CIE system Z801TXB can be manually enrolled to a preferred CIE device via external application software such as Netvox s ZiG BUTLER PC based software or any other 3rd party device For ZiG BUTLER user please refer to ZiG BUTLER section in this manual If registration is successful it flashes 6 times If registration table is full and unable to enroll it flashes 4 times If CIE is ...

Страница 6: ...5 times The device should automatically announce information to the air The device would stay awake for a while but short Restore to factory setting Z801TXB is capable of storing and saving includes network routing information If you wish to remove Z801TXB from the network you would need to clear it to join to a new network by simply reset the device to restore to the factory setting Operation 1 R...

Страница 7: ...er either by an open or a close state of the sensor at the time of device factory default Operation To program Z801TXB to trigger the alarm by a close circuit sensor type 1 Restored the device to factory default setting Refer to restore device to factory setting section in this manual 2 Select a preferred S port and leave it as an open circuit 3 Then power cycle the device The device regards open ...

Страница 8: ...ports Z801TXB 0x00 EMBER_ZCL_IAS_ZONE_TYPE_STANDARD_CIE 0x0000 0x01 EMBER_ZCL_IAS_ZONE_TYPE_MOTION_SENSOR 0x000D 0x02 EMBER_ZCL_IAS_ZONE_TYPE_CONTACT_SWITCH 0x0015 0x03 EMBER_ZCL_IAS_ZONE_TYPE_FIRE_SENSOR 0x0028 0x04 EMBER_ZCL_IAS_ZONE_TYPE_WATER_SENSOR 0x002A 0x05 EMBER_ZCL_IAS_ZONE_TYPE_GAS_SENSOR 0x002B 0x06 EMBER_ZCL_IAS_ZONE_TYPE_PERSONAL_EMERGENCY_DEVICE 0x002C 0x07 EMBER_ZCL_IAS_ZONE_TYPE_V...

Страница 9: ... 0x0000 Identify 0x0003 Optional Power configuration 0x0001 None Attributes of the Basic Information Identifie r Name Type Rang e Access Default Mandator y Optional 0x0000 ZCLVersion Unsigned 8 bit integer 0x00 0xff Read only 0x03 M 0x0001 ApplicationVersion Unsigned 8 bit integer 0x00 0xff Read only 0x1F O 0x0002 StackVersion Unsigned 8 bit integer 0x00 0xff Read only 0x2F O 0x0003 HWVersion Unsi...

Страница 10: ...er string 0 16 bytes Read only 20140210 O 0x0007 PowerSource 8 bit Enumeratio n 0x00 0xff Read only 03 M 0x0010 LocationDescriptio n Character string 0 16 bytes Read writ e O 0x0011 PhysicalEnvironme nt 8 bit Enumeratio n 0x00 0xff Read writ e 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read writ e 0x01 M ...

Страница 11: ...n a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that is higher in temperature This can severely damage the PCB board and circuitry This may shorten the life span of the device damage the battery and cause the housing to deform Do not throw or strongly vibrate the device This may damage connectivity of the electronic par...