background image

Battery disposal

This device uses AAA size battery. When the battery is bellowing 2.4V DC, the device will
not work and the status indicator will steadily flash to notify the user to replace it.

Warning: Do not cast battery into the fire. The battery may be explosive and may cause
injuries.

Installation

Sensor connection

Connect the sensor cable into the signal input ports. One sensor to one signal port
configuration. Also connect the sensor’s negative cable to the common ground port.

Since Z801TXB can be triggered by signal change, Z801TXB sensor selection must be
those that give either open or close circuit configuration.

You may program the device so that it may trigger either by an open or a close state of the
sensor at the time of device factory default.

Operation:

To program Z801TXB to trigger the alarm by

a close circuit sensor type

:

1. Restored the device to factory default setting. (Refer to restore device to factory
setting section in this manual)
2. Select a preferred S port and leave it as

an open circuit

.

3. Then power cycle the device.
The device regards

open circuit

as a normal status and therefore will not trigger the

alarm.

To program Z801TXB to trigger the alarm by

an open circuit sensor type

:

1. Restored the device to factory default setting. (Refer to restore device to factory
setting section in this manual)
2. Select a preferred S port and connect the sensor in such a way that it is

a close

circuit

.

3. Then power cycle the device.
The device regards

a short circuit

as a normal status and therefore will not trigger the

alarm.

Содержание Z801TXB

Страница 1: ...ZigBeeTM Pulse Signal Detector User Manual Pulse Signal Detector Model Z801TXB Compatible with ZigBee Home Automation Profile 201040210 FW V3 1 HW V4 3 V4 4 ...

Страница 2: ...Model Z801TXB Signal 1 Signal 2 Signal 3 Signal 4 Signal 5 Back View Status LED1 Network LED2 GND Binding Key Battery Compartment ...

Страница 3: ...in between wireless markup technology and Bluetooth ZigBee is based on IEEE802 15 4 standard the mutual co ordination between thousands of sensors to exchange data Sensor to sensor or node to node communication is achieved through relays of control data between devices with only a fraction of energy use which denoted for highly transmission efficiency Note Wireless communication in some real use c...

Страница 4: ...ion operation Step 1 Make sure you have opened up permit join function valid for 60 seconds of a coordinator or a router Step 2 Give power to Z801TXB device refer to How to power up the device The device will start to search for the network within reach Step 3 The network status indicator on the Z801TXB will flash 5 times when it finds the network otherwise the indicator stays unchanged If it fail...

Страница 5: ...01TXB to a preferred CIE system Z801TXB can be manually enrolled to a preferred CIE device via external application software such as Netvox s ZiG BUTLER PC based software or any other 3rd party device For ZiG BUTLER user please refer to ZiG BUTLER section in this manual If registration is successful it flashes 6 times If registration table is full and unable to enroll it flashes 4 times If CIE is ...

Страница 6: ...5 times The device should automatically announce information to the air The device would stay awake for a while but short Restore to factory setting Z801TXB is capable of storing and saving includes network routing information If you wish to remove Z801TXB from the network you would need to clear it to join to a new network by simply reset the device to restore to the factory setting Operation 1 R...

Страница 7: ...er either by an open or a close state of the sensor at the time of device factory default Operation To program Z801TXB to trigger the alarm by a close circuit sensor type 1 Restored the device to factory default setting Refer to restore device to factory setting section in this manual 2 Select a preferred S port and leave it as an open circuit 3 Then power cycle the device The device regards open ...

Страница 8: ...ports Z801TXB 0x00 EMBER_ZCL_IAS_ZONE_TYPE_STANDARD_CIE 0x0000 0x01 EMBER_ZCL_IAS_ZONE_TYPE_MOTION_SENSOR 0x000D 0x02 EMBER_ZCL_IAS_ZONE_TYPE_CONTACT_SWITCH 0x0015 0x03 EMBER_ZCL_IAS_ZONE_TYPE_FIRE_SENSOR 0x0028 0x04 EMBER_ZCL_IAS_ZONE_TYPE_WATER_SENSOR 0x002A 0x05 EMBER_ZCL_IAS_ZONE_TYPE_GAS_SENSOR 0x002B 0x06 EMBER_ZCL_IAS_ZONE_TYPE_PERSONAL_EMERGENCY_DEVICE 0x002C 0x07 EMBER_ZCL_IAS_ZONE_TYPE_V...

Страница 9: ... 0x0000 Identify 0x0003 Optional Power configuration 0x0001 None Attributes of the Basic Information Identifie r Name Type Rang e Access Default Mandator y Optional 0x0000 ZCLVersion Unsigned 8 bit integer 0x00 0xff Read only 0x03 M 0x0001 ApplicationVersion Unsigned 8 bit integer 0x00 0xff Read only 0x1F O 0x0002 StackVersion Unsigned 8 bit integer 0x00 0xff Read only 0x2F O 0x0003 HWVersion Unsi...

Страница 10: ...er string 0 16 bytes Read only 20140210 O 0x0007 PowerSource 8 bit Enumeratio n 0x00 0xff Read only 03 M 0x0010 LocationDescriptio n Character string 0 16 bytes Read writ e O 0x0011 PhysicalEnvironme nt 8 bit Enumeratio n 0x00 0xff Read writ e 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read writ e 0x01 M ...

Страница 11: ...n a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that is higher in temperature This can severely damage the PCB board and circuitry This may shorten the life span of the device damage the battery and cause the housing to deform Do not throw or strongly vibrate the device This may damage connectivity of the electronic par...

Отзывы: