background image

 

 

1.

 

 Introduction 

R720FLT is a wireless communication device for netvox ClassA device based on LoRaWAN open protocol.  

The device is connected with two electrode rods to detect the water make-up of the toilet water tank, detect the daily water make-

up times and whether the water tank is faulty, and transmit the detected data to other devices through the wireless network for 

display; Compatible with LoRaWAN protocol. The toilet water tank leakage detection device can cut the electrode rod to the 

required length as required. 

 

 The status of the toilet water tank is determined according to the configured water make-up time (default is 5 minutes). When 

the actual water make-up time of the toilet exceeds the preset time, the toilet water tank is in an abnormal state, and a data package 

of the current voltage value, the current water make-up times and the status is reported. 

 

 Press the key to immediately detect the current voltage value, the current number and status of toilet water tank replenishment, 

and report a current detected data packet. 

 

 Check the water supplement times every 24 hours. If the preset times are exceeded (50 times by default), the toilet water tank 

is in an abnormal state, and report a data package of the current voltage value, current water supplement times and state of the 

toilet water tank. 

 

LoRa Wireless Technology: 

LoRa is a wireless communication technology dedicated to long distance and low power consumption. Compared with other 

communication methods, LoRa spread spectrum modulation method greatly increases to expand the communication distance. 

Widely used in long-distance, low-data wireless communications. For example, automatic meter reading, building automation 

equipment, wireless security systems, industrial monitoring. Main features include small size, low power consumption, 

transmission distance, anti-interference ability and so on. 

 

LoRaWAN: 

LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure interoperability between devices and 

gateways from different manufacturers.  

 

 

 

 

Содержание R720FLT

Страница 1: ...Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other pa...

Страница 2: ...of ReportDataCmd 5 5 2 Example of ConfigureCmd 6 5 3 Example for MinTime MaxTime logic 8 6 Installation 9 7 Information about Battery Passivation 10 7 1 To determine whether a battery requires activa...

Страница 3: ...rent voltage value the current number and status of toilet water tank replenishment and report a current detected data packet Check the water supplement times every 24 hours If the preset times are ex...

Страница 4: ...be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne L...

Страница 5: ...icator remains off fail Had joined the network Turn on the device to search the previous network The green indicator stays on for 5 seconds success The green indicator remains off fail Fail to join th...

Страница 6: ...plenishments in the toilet water tank within 24 hours is abnormal Replenish water count Replenishwatercount is the cumulative make up times of the toilet water tank When the device is powered off clea...

Страница 7: ...2F Replenish water count 2F Hex 47 Dec 9th byte 00 Fault Alarm no alarm 10th byte 00 Tank Leak Alarm no alarm 11th byte 00 Reserved Example of uplink 2 01D4019F00000168010000 1st byte 01 Version 2nd b...

Страница 8: ...000000 configuration failure 2 Read R720 FLT device parameter Downlink 02D4000000000000000000 Device return 82D4003C003C0100000000 device current parameter Description Device Cmd ID Device Type Netvox...

Страница 9: ...le for MinTime MaxTime logic Example 1 based on MinTime 1 Hour MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime MaxTime Sleeping MinTime Sleeping MinTime Note MaxTime MinTime Dat...

Страница 10: ...tank leakage detection equipment Step1 Open the toilet water tank cover Step 2 Press the handle gently to drain water until the toilet begins to replenish water Record the water level at this time nam...

Страница 11: ...rding to the installation steps 7 Information about Battery Passivation Many of Netvox devices are powered by 3 6V ER14505 Li SOCl2 lithium thionyl chloride batteries that offer many advantages includ...

Страница 12: ...5 Battery Passivation 7 1 To determine whether a battery requires activation Connect a new ER14505 battery to a resistor in parallel and check the voltage of the circuit If the voltage is below 3 3V i...

Страница 13: ...he battery into the fire to prevent the battery from exploding Damaged batteries may also explode All the above suggestions apply equally to your device batteries and accessories If any device is not...

Отзывы: