5
5.
Data Report
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable Change
Current Change
≥
Reportable Change
Current Change
<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval
When the device is turned on, it will immediately send a version package and a data report of parking status and battery
voltage.
The device sends data in the default configuration before any configuration is done.
Default setting:
ReportMaxTime: 3600s
ReportMinTime: 3600s (to detect the current voltage value per Min Interval)
Battery voltage: 0x01(0.1V)
Geomagnetic Detect Threshold: 0x28 (40) *Range:0x14-0xFFFF (0x14 is the most sensitivity)
Vehicle parking trigger:
When a car parked, 15 seconds later, sensor would send a data
“
CarOnOff” =01, which means that the space is parked.
When a car left, 15 seconds later, sensor would send a data “CarOnOff” =00, which means that the space is empty to park.
The parking space status will be reported according to configuration.
Note:
The device report interval will be programmed based on the default firmware which may vary.
The interval between two reports must be ReportMinTime.
Please refer Netvox
LoRaWAN Application Command document
and
Netvox Lora Command Resolver
http://loraresolver.netvoxcloud.com:8888/page/index
to resolve uplink data.