6
Report Configuration
Fport:0x07
(1) Configure device parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v,
Downlink: 0159003C003C0100000000
The device returns:
8159000000000000000000 (configuration successful)
8159010000000000000000 (configuration failed)
(2) Read device parameters
Downlink: 0259000000000000000000
The device returns:
8259003C003C0100000000 (current device configuration parameters)
Geomagnetic Threshold Configuration
Fport: 0x07
(It is not recommended to modify the default settings of the device to prevent incorrect setting, which will cause false detection of
parking status)
Description
Device
Cmd
ID
Device
Type
NetvoxPayLoadData
Config
ReportReq
R719A
0x01
0x59
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Reserved
(4Bytes,Fixed 0x00)
Config
ReportRsp
0x81
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes,Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Reserved
(4Bytes,Fixed
0x00)
Description
Device
Cmd
ID
Device
Type
NetvoxPayLoadData
Description
SetDetect
ThresholdReq
R719A 0x03
0x59
DetectThreshold(2bytes)
Reserved (7Bytes,Fixed 0x00)