Configure the device parameter MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v, DistanceChange = 500mm
Downlink: 01B1003C003C0101F40000
Device Return:
81B1000000000000000000 (configuration success)
81B1010000000000000000 (configuration failure)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit: s)
MaxTime
(2bytes Unit: s)
BatteryChange
(1byte Unit: 0.1v)
DistanceChange
(2byte Unit:
1mm)
Reserved
(2byte)
SetOnDistance
ThresholdRreq
0x03
OnDistanceThreshold
(2byte Unit: 1mm)
Reserved
(7Bytes, Fixed 0x00)
SetOnDistance
ThresholdRrsp
0x83
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
GetOnDistance
ThresholdRreq
0x04
Reserved
(9Bytes, Fixed 0x00)
GetOnDistance
ThresholdRrsp
0x84
OnDistanceThreshold
(2byte Unit: 1mm)
Reserved
(7Bytes, Fixed 0x00)
SetFillMax
DistanceReq
0x05
FillMaxDistance
(2byte Unit: 1mm)
Reserved
(7Bytes, Fixed 0x00)
SetFillMax
DistanceRsp
0x85
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
GetFillMax
DistanceReq
0x06
Reserved
(9Bytes, Fixed 0x00)
GetFillMax
DistanceRsp
0x86
FillMaxDistance
(2byte Unit: 1mm)
Reserved
(7Bytes, Fixed 0x00)
SetDeadZone
DistanceReq
0x0B
DeadZoneDistance
(2byte Unit:1mm)
Reserved
(7Bytes,Fixed 0x00)
SetDeadZone
DistanceRsp
0x8B
Status(0x00_success)
Reserved (8Bytes,Fixed 0x00)
GetDeadZone
DistanceReq
0x0C
Reserved (9Bytes,Fixed 0x00)
GetDeadZone
DistanceReq
0x8C
DeadZoneDistance (2byte Unit:1mm)
Reserved (7Bytes,Fixed 0x00)