6
5. Data Report
5.1 Example of ReportDataCmd
FPort
:
0x06
Bytes
1
1
1
Var(Fix=8 Bytes)
Version
DeviceType
ReportType
NetvoxPayLoadData
Version
– 1 byte –0x01
——
the Version of NetvoxLoRaWAN Application Command Version
DeviceType
– 1 byte – Device Type of Device
The devicetype is listed in Netvox LoRaWAN Application Devicetype doc
ReportType
– 1 byte –the presentation of the NetvoxPayLoadData
,
according the devicetype
NetvoxPayLoadData
– Fixed bytes (Fixed =8bytes)
After power on, the device will immediately send a version packet report and an attribute packet report.
The device sends data according to the default configuration before any other configuring.
Default Setting
Maximum time: Max Interval = 15 min
Minimum time: Min Interval = 15 min
BatteryVoltageChange - 0x01 (0.1V)
DistanceChange - 0x012C(300mm)
Data packet:
a.
When used in iquid level detection:
Distance, FillLevel;
Status=0 (Invalid)
b.
When used in parking detection: Status, Distance;
FillLevel=0 (Invalid)
Note:
1.
The cycle of the device sending the data report is according to the default.
2.
The interval between two reports must be the MinTime
3.
R718PE report battery voltage, status, distance, fill level
Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver
http://www.netvox.com.cn:8888/page/index to resolve uplink data.