background image

 

 

            8157000000000000000000 (configuration success) 

            8157010000000000000000 (configuration failure) 

 

(2)    Read R718PA11 device parameter 

     Downlink: 0257000000000000000000 

     Device Return: 

            8257000A003C0000000000 (device current parameter) 

 

Example Of The Liquid Level Range Configuration 

Description  Device 

Cmd 

ID 

Device 

Type 

NetvoxPayLoadData 

SetWireLen

gthReq 

R718PA

11 

0x08 

0x57 

Length 

(2bytes, Unit:1dm) 

Reserved   

(7Bytes, Fixed 0x00) 

SetWireLen

gthRsp 

0x88 

Status (0x00_success) 

Reserved   

(8Bytes, Fixed 0x00) 

GetWireLe

ngthReq 

0x09 

Reserved (9Bytes, Fixed 0x00) 

GetWireLe

ngthRsp 

0x89 

Length 

(2bytes, Unit:1dm) 

Reserved   

(7Bytes, Fixed 0x00) 

(1)  Configure R718PA11 device parameter Lenght= 30dm 

     Downlink: 0857001E00000000000000 

     Device Return: 

            8857000000000000000000 (configuration success) 

            8857010000000000000000 (configuration failure) 

 

(2)    Read R718PA11 device parameter 

     Downlink: 0957000000000000000000 

     Device Return: 

            8957001E00000000000000 (device current parameter) 

Содержание R718PA11

Страница 1: ...ogy Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties i...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Feature 3 4 Set Up Instruction 4 5 Data Report 5 6 Installation 7 7 Important Maintenance Instruction 8...

Страница 3: ...ption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communicati...

Страница 4: ...on object Host body protection level IP65 67 Compatible with LoRaWANTM Class A Frequency hopping spread spectrum technology Configuring parameters and reading data via the third party software platfor...

Страница 5: ...network The green indicator keeps on for 5 seconds success The green indicator remains off fail Had Joined the Network Not in the original setting Turn on the device to search the previous network Th...

Страница 6: ...R718PA11 reports the value of the liquid level The device reported data parsing please refer to Netvox LoraWAN Application Command document and Netvox Lora Command Resolver http loraresolver netvoxclo...

Страница 7: ...57 Length 2bytes Unit 1dm Reserved 7Bytes Fixed 0x00 SetWireLen gthRsp 0x88 Status 0x00_success Reserved 8Bytes Fixed 0x00 GetWireLe ngthReq 0x09 Reserved 9Bytes Fixed 0x00 GetWireLe ngthRsp 0x89 Leng...

Страница 8: ...he device in a metal shielded box or in an environment surrounded by other electrical equipment to avoid affecting the wireless transmission of the device 2 R718PA11 regularly reports the data of the...

Страница 9: ...stic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device...

Отзывы: