background image

 

 

4.

 

Set Up Instruction 

On/Off 

Power On 

DC 12V adapter 

Turn On 

Press and hold the function key for 3 seconds till the green indicator 

flashes once. 

Turn Off 

(Restore to factory setting) 

Press and hold the function key for 5 seconds, and the green indicator 

flashes 20 times. 

Power Off 

Remove DC12V adapter 

Note 

1.

 

On/off interval is suggested to be about 10 seconds to avoid the 
interference of capacitor inductance and other energy storage 
components. 

2.

 

The first five seconds after power on, the device will be in 
engineering test mode. 

Network Joining 

Never Join the Network 

Turn on the device to search the network. 

The green indicator keeps on for 5 seconds: success. 

The green indicator remains off: fail 

Had Joined the Network 

(Not in the original setting) 

Turn on the device to search the previous network. 

The green indicator keeps on for 5 seconds: success. 

The green indicator remains off: fail. 

Fail to Join the Network 

Suggest to check the device registration information on the   

gateway or consulting your platform server provider if the device 

fails to join the network. 

Function Key 

Press and Hold for 5 Seconds 

Restore to the original setting / turn off 

The green indicator flashes 20 times: success 

The green indicator remains off: fail 

Press once 

The device is in the network: the green indicator flashes once and 

the device sends a data report 

The device is not in the network: the green indicator remains off 

Содержание R718PA11

Страница 1: ...ogy Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties i...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Feature 3 4 Set Up Instruction 4 5 Data Report 5 6 Installation 7 7 Important Maintenance Instruction 8...

Страница 3: ...ption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communicati...

Страница 4: ...on object Host body protection level IP65 67 Compatible with LoRaWANTM Class A Frequency hopping spread spectrum technology Configuring parameters and reading data via the third party software platfor...

Страница 5: ...network The green indicator keeps on for 5 seconds success The green indicator remains off fail Had Joined the Network Not in the original setting Turn on the device to search the previous network Th...

Страница 6: ...R718PA11 reports the value of the liquid level The device reported data parsing please refer to Netvox LoraWAN Application Command document and Netvox Lora Command Resolver http loraresolver netvoxclo...

Страница 7: ...57 Length 2bytes Unit 1dm Reserved 7Bytes Fixed 0x00 SetWireLen gthRsp 0x88 Status 0x00_success Reserved 8Bytes Fixed 0x00 GetWireLe ngthReq 0x09 Reserved 9Bytes Fixed 0x00 GetWireLe ngthRsp 0x89 Leng...

Страница 8: ...he device in a metal shielded box or in an environment surrounded by other electrical equipment to avoid affecting the wireless transmission of the device 2 R718PA11 regularly reports the data of the...

Страница 9: ...stic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device...

Отзывы: