background image

 

 

4.

 

Set Up Instruction 

On/Off 

 

Power On 

DC12V adapter 

Turn On 

DC12V power supply, the green indicator flashing once means turn on successfully. 

Restore To Factory Setting 

Press and hold the function key for 5 seconds, and the green indicator flashes 20 times. 

Power Off 

Remove DC12V adapter 

Note 

1.

 

On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor 

inductance and other energy storage components. 

2.

 

The first 5 seconds after power on, the device will be in engineering test mode. 

Network Joining 

 

Never Join the Network 

Turn on the device to search the network. 

The green indicator keeps on for 5 seconds: success. 

The green indicator remains off: fail 

Had Joined the Network 

(Not restore to the factory setting) 

Turn on the device to search the previous network. 

The green indicator keeps on for 5 seconds: success. 

The green indicator remains off: fail. 

Fail to Join the Network 

Suggest checking the device registration information on the gateway or consulting your 

platform server provider if the device fails to join the network. 

Function Key 

 

Press and Hold for 5 Seconds 

Restore to the original setting 

The green indicator flashes 20 times: success 

The green indicator remains off: fail 

Press once 

The device is in the network: the green indicator flashes once and the device sends a data 

report 

The device is not in the network: the green indicator remains off 

 

 

 

 

 

 

 

 

 

 

 

Содержание R718PA Series

Страница 1: ...td This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Feature 3 4 Set Up Instruction 4 5 Data Report 5 6 Installation 7 7 Important Maintenance Instruction 9...

Страница 3: ...low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wir...

Страница 4: ...ass A Frequency hopping spread spectrum technology Configuring parameters and reading data via the third party software platforms and set alarms via SMS text and email optional Applicable to the third...

Страница 5: ...The green indicator keeps on for 5 seconds success The green indicator remains off fail Had Joined the Network Not restore to the factory setting Turn on the device to search the previous network The...

Страница 6: ...ex Example of ReportDataCmd FPort 0x06 Bytes 1 1 1 Var Fix 8 Bytes Version DeviceType ReportType NetvoxPayLoadData Version 1 byte 0x01 the Version of NetvoxLoRaWAN Application Command Version DeviceTy...

Страница 7: ...157000000000000000000 configuration success 8157010000000000000000 configuration failure 1 Read R718PA10 device parameter Downlink 0257000000000000000000 Device Return 8257000A003C0000000000 device cu...

Страница 8: ...or in an environment surrounded by other electrical equipment to avoid affecting the wireless transmission of the device 2 R718PA10 regularly reports the data of the turbidity value and the temperatu...

Страница 9: ...ntenance Method 1 External Surface of The Sensor Use tap water to clean the external surface of the sensor If there are still debris remaining wipe it with a moistened soft cloth For some stubborn dir...

Страница 10: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: