Note: 

1.

 

The probe contains sensitive optical and electronic components. Make sure that the probe is not subject to severe mechanical 

shocks. There are no parts inside the probe that need users’ maintenance. 

2.

 

The black plastic cap on the head of the turbidity sensor should be removed during the test; otherwise, it will affect the 

measurement. 

 

 

 

 

Maintenance Method 

1.

 

External Surface of The Sensor:   

Use tap water to clean the external surface of the sensor. If there are still debris remaining, wipe it with a moistened soft cloth. 

For some stubborn dirt, users can add some household detergent to the tap water to clean it. 

 

2.

 

Check the Cable of The Sensor:   

The  cable  should  not  be  taut  during  normal  operation;  otherwise,  the  internal  wires  of  the  cable  may  break  and  the  sensor 

cannot work normally. 

 

3.

 

Check whether the measuring part of the sensor is dirty, and whether the cleaning brush is normal. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание R718PA Series

Страница 1: ...td This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Feature 3 4 Set Up Instruction 4 5 Data Report 5 6 Installation 7 7 Important Maintenance Instruction 9...

Страница 3: ...low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wir...

Страница 4: ...ass A Frequency hopping spread spectrum technology Configuring parameters and reading data via the third party software platforms and set alarms via SMS text and email optional Applicable to the third...

Страница 5: ...The green indicator keeps on for 5 seconds success The green indicator remains off fail Had Joined the Network Not restore to the factory setting Turn on the device to search the previous network The...

Страница 6: ...ex Example of ReportDataCmd FPort 0x06 Bytes 1 1 1 Var Fix 8 Bytes Version DeviceType ReportType NetvoxPayLoadData Version 1 byte 0x01 the Version of NetvoxLoRaWAN Application Command Version DeviceTy...

Страница 7: ...157000000000000000000 configuration success 8157010000000000000000 configuration failure 1 Read R718PA10 device parameter Downlink 0257000000000000000000 Device Return 8257000A003C0000000000 device cu...

Страница 8: ...or in an environment surrounded by other electrical equipment to avoid affecting the wireless transmission of the device 2 R718PA10 regularly reports the data of the turbidity value and the temperatu...

Страница 9: ...ntenance Method 1 External Surface of The Sensor Use tap water to clean the external surface of the sensor If there are still debris remaining wipe it with a moistened soft cloth For some stubborn dir...

Страница 10: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: