8
Description
Device
Cmd
ID
Device
Type
NetvoxPayLoadData
ConfigReport
Req
R718
EB
0x01
0xC8
MinTime
(2bytes, Unit: s)
MaxTime
(2bytes, Unit: s)
BatteryChange
(1byte, Unit: 0.1v)
AngleChange
(2byte, Unit: 0.1°)
Reserved
(2Bytes, Fixed
0x00)
ConfigReport
Rsp
0x81
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes,Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes, Unit: s)
MaxTime
(2bytes, Unit: s)
BatteryChange
(1byte, Unit: 0.1v)
AngleChange
(2byte, Unit: 0.1°)
Reserved
(2Bytes, Fixed
0x00)
SetActive
ThresholdReq
0x03
Threshold
(2Bytes)
InActivetime
(1Bytes,
Unit: 1s)
Reserved
(5Bytes, Fixed 0x00)
SetActive
ThresholdRsp
0x83
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
GetActive
ThresholdReq
0x04
Reserved
(9Bytes, Fixed 0x00)
GetActive
ThresholdRsp
0x84
Threshold (2Bytes)
InActivetime
(1Bytes, Unit: 1s)
Reserved
(5Bytes, Fixed 0x00)
(1)
Configure device parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v, AngleChange = 5°
Downlink: 01C8003C003C0100320000 003C(H
ex)
= 60(D
ec) ;
0032(H
ex)
= 50(D
ec)
Device returns:
81C8000000000000000000 (configuration is successful)
81C8010000000000000000 (configuration failed)
(2)
Read device parameters
Downlink: 02C8000000000000000000
Device returns:
82C8003C003C0100320000 (current device parameters)