8. Information about Battery Passivation 

Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many 

advantages including low self-discharge rate and high energy density.      

 

However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium 

anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high. This lithium chloride 

layer prevents rapid self-discharge caused by continuous reaction between lithium and thionyl chloride, but battery passivation 

may also lead to voltage delay when the batteries are put into operation, and our devices may not work correctly in this situation.    

 

As a result, please make sure to source batteries from reliable vendors, and it is suggested that if the storage period is more 

than one month from the date of battery production, all the batteries should be activated. 

 

 

If encountering the situation of battery passivation, users can activate the battery to eliminate the battery hysteresis. 

 

ER14505 Battery Passivation: 

8.1 To determine whether a battery requires activation 

Connect a new ER14505 battery to a resistor in parallel, and check the voltage of the circuit. 

If the voltage is below 3.3V, it means the battery requires activation.   

 

8.2 How to activate the battery 

a. Connect a battery to a resistor in parallel   

b. Keep the connection for 5~8 minutes 

c. The voltage of the circuit should be 

3.3, indicating successful activation. 

 

Brand 

Load Resistance 

Activation Time 

Activation Current 

NHTONE 

165 Ω 

5 minutes 

20mA 

RAMWAY 

67 Ω 

8 minutes 

50mA 

EVE 

67 Ω 

8 minutes 

50mA 

SAFT 

67 Ω 

8 minutes 

50mA 

Note:   

If  you  buy  batteries  from  other  than  the  above  four  manufacturers,  then  the  battery  activation  time, activation  current,  and 

required load resistance shall be mainly subject to the announcement of each manufacturer. 

Содержание R718EB

Страница 1: ...ietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written perm...

Страница 2: ...ActiveThreshold and InActiveThreshold 7 6 2 Calibration 7 6 3 Example of data configuration 7 6 4 Example for MinTime MaxTime logic 9 7 Installation 10 8 Information about Battery Passivation 11 8 1...

Страница 3: ...ology dedicated to long distance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widel...

Страница 4: ...can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption and long battery life Battery Life Plea...

Страница 5: ...ver joined the network Turn on the device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to sea...

Страница 6: ...erval Battery Change 0x01 0 1v Angle Change 0xC8 1 The accuracy is 3 in horizontal position Angle of Three axis If the three axis acceleration of the device exceeds ActiveThreshold and the tilt angle...

Страница 7: ...2 Calibration The accelerometer is a mechanical structure that contains components that can move freely These moving parts are very sensitive to mechanical stress far beyond solid state electronics Th...

Страница 8: ...e ThresholdReq 0x03 Threshold 2Bytes InActivetime 1Bytes Unit 1s Reserved 5Bytes Fixed 0x00 SetActive ThresholdRsp 0x83 Status 0x00_success Reserved 8Bytes Fixed 0x00 GetActive ThresholdReq 0x04 Reser...

Страница 9: ...e 1 Hour MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime MaxTime Sleeping MinTime Sleeping MinTime Note MaxTime MinTime Data will only be report according to MaxTime MinTime dur...

Страница 10: ...etected building pole is in static status It is recommended to install the device horizontally After the fixation is completed please power on the device The device performs offset calibration after i...

Страница 11: ...orage period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to eli...

Страница 12: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: