5. Data Report 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

   
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Data report configuration and sending period are as following: 

 

 

 

 

 

 

 

 

Min Interval 

(Unit:second) 

Max Interval 

(Unit:second) 

Reportable Change 

Current Change

≥ 

Reportable Change 

Current Change

Reportable Change 

Any number between 

1~65535 

Any number between 

1~65535 

Can not be 0 

Report 

per Min Interval 

Report 

per Max Interval 

The device will immediately send a version packet report and the vibration report data 

The device sends data in the default configuration before any configuration is done. 

Default setting: 

MaxTime: Max Interval = 60 min = 3600s 

MinTime: Min Interval = 60 min = 3600s 

BatteryVoltageChange: 0x01 (0.1V) 

R718DB trigger: 

When any way of the sensor senses the vibration and the spring deforms, an alarm message willbe reported. 

The vibration is “1”.   

No vibration is “0”. 

The vibration Restore Configuration: 

The Restore function is used to send the final static status of the device. 

(Please refer to the configuration command format below.) 

Restore = 0, no data will be sent when the device is rest. 

The data is sent with the next report. 

Restore = 1, the data will be sent with a vibration bit-- 0 after the device is rest for 5 seconds. 

 

Note: 

The device report interval will be programmed based on the default firmware which may vary. 

The interval between two reports must be the minimum time. 

Please refer Netvox 

LoRaWAN Application Command document

 and 

Netvox Lora Command Resolver

 

http://loraresolver.netvoxcloud.com:8888/page/index

 to resolve uplink data. 

Содержание R718DB

Страница 1: ...ology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Important Maintenance Instruction 10...

Страница 3: ...dulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equipment w...

Страница 4: ...ctrum technology Configuration parameters can be configured through third party software platforms Data can be read and alerts can be set via SMS text and email optional Applicable to third party plat...

Страница 5: ...tor stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network to join The green indicator stays on for 5 seconds succ...

Страница 6: ...trigger When any way of the sensor senses the vibration and the spring deforms an alarm message willbe reported The vibration is 1 No vibration is 0 The vibration Restore Configuration The Restore fu...

Страница 7: ...00 Configuration failure 2 Read device configuration parameters Downlink 021B000000000000000000 Response 821B003C003C0100000000 Current configuration Description Device CmdID Device Type NetvoxPayLoad...

Страница 8: ...stops vibrating Downlink 031B010000000000000000 0x01_DO report when sensor restore Response 831B000000000000000000 Configuration success 831B010000000000000000 Configuration failure 2 Read restore fun...

Страница 9: ...recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matte...

Страница 10: ...is vibrating here take the mousetrap as a picture Video link Mouse trap 3 The figure shows the vibration sensor R718DB applied to the scene of the mousetrap in the restaurant It can also be applied t...

Страница 11: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...