background image

 

 

4.Set up Instruction

 

On/Off 

 

Power on 

Insert batteries (Users may need a screwdriver to open) 

Turn on   

Press and hold the function key for 3 seconds and the green indicator flash once.   

Turn off (Restore to factory setting)  Press and hold the function key for 5 seconds and the green indicator flashes 20 times. 

Power off 

Remove Batteries.   

Note: 

1.

 

Remove and insert the battery; the device is at off state by default.

 

2.

 

On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor 

inductance and other energy storage components. 

3.

 

For the first 5 second after powering on, the device will be in engineering test mode.   

Network Joining 

 

Never joined the network 

Turn on the device to search the network to join. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Had joined the network 

Turn on the device to search the previous network to join. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Fail to join the network   

(when the device is on) 

Suggest to check the device verification information on the gateway or consult your platform 

server provider. 

Function Key 

 

Press and hold for 5 seconds 

Restore to factory setting / Turn off 

The green indicator flashes 20 times: success 

The green indicator remains off: fail 

Press once   

The device is in the network: the green indicator flashes once and sends a report 

The device is not in the network: the green indicator remains off 

Sleeping Mode 

 

The device is on and in the network 

Sleeping period: Min Interval. 

When the reportchange exceeds setting value or the state changes: send a data report according 

to Min Interval.   

Low Voltage Warning 

Low Voltage 

3.2V 

 

 
 
 

Содержание R718DB

Страница 1: ...ology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Important Maintenance Instruction 10...

Страница 3: ...dulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equipment w...

Страница 4: ...ctrum technology Configuration parameters can be configured through third party software platforms Data can be read and alerts can be set via SMS text and email optional Applicable to third party plat...

Страница 5: ...tor stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network to join The green indicator stays on for 5 seconds succ...

Страница 6: ...trigger When any way of the sensor senses the vibration and the spring deforms an alarm message willbe reported The vibration is 1 No vibration is 0 The vibration Restore Configuration The Restore fu...

Страница 7: ...00 Configuration failure 2 Read device configuration parameters Downlink 021B000000000000000000 Response 821B003C003C0100000000 Current configuration Description Device CmdID Device Type NetvoxPayLoad...

Страница 8: ...stops vibrating Downlink 031B010000000000000000 0x01_DO report when sensor restore Response 831B000000000000000000 Configuration success 831B010000000000000000 Configuration failure 2 Read restore fun...

Страница 9: ...recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matte...

Страница 10: ...is vibrating here take the mousetrap as a picture Video link Mouse trap 3 The figure shows the vibration sensor R718DB applied to the scene of the mousetrap in the restaurant It can also be applied t...

Страница 11: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: