Disabletime and Detectiontime
Once the device enters the DisableTime, it will stop detecting for the first 70% period of the DisableTime, and it will be back to
detection for the remaining 30% of the DisableTime. If pressure/occupancy is detected during the remaining 30% of the
DisableTime, R313WA will enter the next period of DisableTime.
Example1:
While DetectionTime is 60 secs and DisableTime is 30 secs,
no pressure
is detected after triggered.
R313WA will report un-pressure after 60 secs (DetectionTime).
Example2:
While DetectionTime is 60 secs and DisableTime is 30 secs,
pressure
is detected during 25th sec.
R313WA will restart pressure detect procedure
(DetectionTime).
No pressure is detected during next DetectionTime and R313WA therefore report un-pressure