background image

 

 

Note:   

1)

 

The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not collect   

data. 

2)

 

The data collected is compared with the last data reported. If the data change value is greater than the ReportableChange value, 

the device reports according to MinTime interval. If the data variation is not greater than the last data reported, the device   

reports according to MaxTime interval. 

3)

 

We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is too low, the device wakes up   

frequently and the battery will be drained soon. 

4) Whenever the device sends a report, no matter resulting from data variation, button pushed or MaxTime interval, another cycle   

  

of MinTime / MaxTime calculation is started. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание R312A

Страница 1: ...This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 10 7 Important Maintenance Instruction 11...

Страница 3: ...spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building aut...

Страница 4: ...m Configuration parameters can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility Thi...

Страница 5: ...network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on the device to search the previous network...

Страница 6: ...r Max Interval The device will immediately send a version packet report along with an uplink packet including alarm status The device sends data in the default configuration before any configuration i...

Страница 7: ...0000000 Configuration failure 2 Read Configuration Downlink 024D000000000000000000 Response 824D003C003C0100000000 Current configuration Description Device Cmd ID Device Type NetvoxPayLoadData Config...

Страница 8: ...iguration Description CmdID PayLoad Fix byte 1byte SetButtonPressTimeReq 0x01 PressTime 1byte 0x00_QuickPush_Less then 1 Second 0x01_1 Second push 0x02_2 Seconds push 0x03_3 Seconds push 0x04_4 Second...

Страница 9: ...M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 2 8V Does not report Wakes up and collects data REPORTS 2 8V Wakes up and collects data REPORT 2 8V Wakes up and collects data REPO...

Страница 10: ...ts according to MinTime interval If the data variation is not greater than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval val...

Страница 11: ...neck with a lanyard Note Do not install the device in a metal shielded box or other electrical equipment around it to avoid affecting the wireless transmission of the device The emergency button R312...

Страница 12: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...