Example of Config Button Press Time 

 

FPort

0x0D

       

 

Default Press Time

0x03 

(1)

 

Command Configuration: 

      Trigger doorbell after press button 2 seconds 

     Downlink

0102          *Please notice port number is 0x0D (13) when downlink command 

     Response

8100 (Configuration success) 

               8101 (Configuration failure) 

(1)

 

Read Configuration: 

     Downlink

02 

     Response

 

               8202

Current configuration

 

Description 

CmdID 

PayLoad

 

(Fix byte,1byte) 

SetButtonPressTimeReq 

0x01 

PressTime 

(1byte, 

0x00_QuickPush_Less then 1 Second, 

0x01_1 Second push, 

0x02_2 Seconds push, 

0x03_3 Seconds push, 

0x04_4 Seconds push, 

0x05_5 Seconds push, 

Other value is reserved) 

SetButtonPressTimeRsp 

0x81 

Status 

(0x00_Success 

0x01_Failure) 

GetButtonPressTimeReq 

0x02 

 

GetButtonPressTimeRsp 

0x82 

PressTime

 

(1byte, 

0x00_QuickPush_Less then 1 Second, 

0x01_1 Second push, 

0x02_2 Seconds push, 

0x03_3 Seconds push, 

0x04_4 Seconds push, 

0x05_5 Seconds push, 

Other value is reserved) 

Содержание R312A

Страница 1: ...This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 10 7 Important Maintenance Instruction 11...

Страница 3: ...spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building aut...

Страница 4: ...m Configuration parameters can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility Thi...

Страница 5: ...network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on the device to search the previous network...

Страница 6: ...r Max Interval The device will immediately send a version packet report along with an uplink packet including alarm status The device sends data in the default configuration before any configuration i...

Страница 7: ...0000000 Configuration failure 2 Read Configuration Downlink 024D000000000000000000 Response 824D003C003C0100000000 Current configuration Description Device Cmd ID Device Type NetvoxPayLoadData Config...

Страница 8: ...iguration Description CmdID PayLoad Fix byte 1byte SetButtonPressTimeReq 0x01 PressTime 1byte 0x00_QuickPush_Less then 1 Second 0x01_1 Second push 0x02_2 Seconds push 0x03_3 Seconds push 0x04_4 Second...

Страница 9: ...M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 2 8V Does not report Wakes up and collects data REPORTS 2 8V Wakes up and collects data REPORT 2 8V Wakes up and collects data REPO...

Страница 10: ...ts according to MinTime interval If the data variation is not greater than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval val...

Страница 11: ...neck with a lanyard Note Do not install the device in a metal shielded box or other electrical equipment around it to avoid affecting the wireless transmission of the device The emergency button R312...

Страница 12: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: