Wiring Diagrams: 24vac/dc Models

Direct 24vac/dc Powered

120vac to 24vac/dc Powered

  Black

  Hot

  Green

  Ground

  White

  Neutral

120vac

1.

 Connect your annunciator’s audio output to the TB1 connection 

    on this board.

2.

 When utilizing this board to drive a 24v LED, you must apply 

    power to the wire leads at the TB2 connection. You may tap into 
    a direct 24vdc supply that has battery backup. Connect the wire 
    leads at the J5 connection to your LED.

3.

 If you are not utilizing this board to drive a 24v LED, you need 

    to disconnect the LED harness from the SmartPhone board, 
    disconnect the LED harness from this board, connect it to the 
    SmartPhone board, and then wire to your standard LED.

4.

 If you want to activate Relay 2 in unison with Alarm Relay on

    SmartPhone board, follow these programming steps (default 
    activates upon call out):
 a. 

Press 

ENTER

 b. 

Press 

3, 0, ENTER, 4

 c. 

Press 

STOP

 for 3 seconds

To 24vac/dc

Power Supply

To Phone Line:

Requires a twisted 

shielded pair. 

When used with 

SmartRescue, 

requires two 

twisted shielded 

pairs.

To Phone Line:

Requires a twisted 

shielded pair. 

When used with 

SmartRescue, 

requires two 

twisted shielded 

pairs.

Note:

If Elevator

Communications 

Failure is required,

connect to our 

Alarm Relay 

*

RP8200950

Ver. 9

09/19

Annunciator Interface,

Auxiliary Relay & 24v LED Board 

To Speaker

Relay 1

Relay 2

To H1 on SP VI

To Speaker connection 

on SP VI Circuit Board

To Audio output

of Annunciator

To LED on SPVI

24v LED

24vdc Power for LED

TB2

J5

- +

- +

- +

J3

J4

J1

J2

TB1

AUX1

AUX2

COM

NC

NO

COM

NC

NO

Relay Alarm

LED    Switch

   MIC    Speaker

Bat

24vac/dc

RJ1

1

 1       2       3

 4       5       6

 7       8       9

0       #

Enter

Record

Play/Pause

Stop

*

RJ1

1

Relay Alarm

LED    Switch

   MIC    Speaker

Bat

RJ1

1

 1       2       3

 4       5       6

 7       8       9

0       #

Enter

Record

Play/Pause

Stop

*

RJ1

1

Note:

If Elevator

Communications 

Failure is required,

connect to our 

Alarm Relay 

*

24v

  RP7300144-24/5VA