8. Installation 

8. Installation   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.Remove the 3M adhesive on the back of the

 

Activity Timer and attach the body to the surface 

of a smooth object 

(please do not stick it to a 

rough surface to prevent the device from 

falling off after a long time use).

 

 

Note

 

 

Wipe the surface clean before installation 

to avoid dust on  the surface to  affect the 

adhesion of the device. 

 

Do not install the device in a metal 

shielded box or other electrical equipment 

around it to avoid affecting the wireless 

transmission of the device. 

2. When the device detects a sudden movement 

or vibration of the object (or electrical 

machinery). 

  Wait for a certain period of time (DeactiveTime- 

default 5 seconds , can be modified) to enter the 

quiescent state and it sends a report of duration of 

vibrations, and restarts the calculation for the 

next detection, the timer data will clear. 

 

Note

 

 If the vibration continues to occur during this 

process (quiescent state), the timer continue 

calculation until the device enter the quiescent 

state. 

 
 
 
 
 
 
 
 
 

Activity Timer (R311FC)  is suitable for the following 

scenarios: 

Industrial Equipment 

Industrial Instrument 

Medical Instruments 

When it necessary to detect the motor running time. 

Содержание R311FC

Страница 1: ...Model R311FC Wireless Activity Timer Wireless Activity Timer User Manual...

Страница 2: ...struction 4 4 1 Power on and Turn on off 4 4 2 Join Into Lora Network 4 4 3 Function Key 5 4 4 Data Report 5 5 Restore to Factory Setting 9 6 Sleeping Mode 9 7 Low Voltage Alarming 9 8 Installation 10...

Страница 3: ...tion methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter rea...

Страница 4: ...3 2 Appearance...

Страница 5: ...Turn off Press and hold function key for 5 seconds till the green indicator flashes quickly and release The green indicator will flash 20 times to show that R311FC is turned off 4 Remove batteries po...

Страница 6: ...um time The data content is R311FC current device status 2 R311FC device will only report according to the minimum time when the battery voltage changes R311FC vibration alarm The device detects sudde...

Страница 7: ...ype 1Bytes 0x01_R311FA 0x02_R311FB 0x03_R311FC Reserved 8Bytes Fixed 0x00 SetActive ThresholdReq 0x05 Threshold 2Bytes Deactivetime 1Byte Unit 1s Reserved 6Bytes Fixed 0x00 SetActive ThresholdRsp 0x85...

Страница 8: ...000 configuration failed 4 Read device type Downlink 0451000000000000000000 The device returns 8451020000000000000000 current device type R311FB Example 1 based on MinTime 1 Hour MaxTime 1 Hour Report...

Страница 9: ...rts according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon...

Страница 10: ...evice is in the network the sleeping period is Min Interval During this period if the reportchange is larger than setting value it will wake up and send a data report B When it is not in the network R...

Страница 11: ...transmission of the device 2 When the device detects a sudden movement or vibration of the object or electrical machinery Wait for a certain period of time DeactiveTime default 5 seconds can be modifi...

Страница 12: ...Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy intern...

Отзывы: