34
|
Chapter 2. Configuring System Information
ProSafe® Gigabit L3 Managed Stackable Switches Software Administration Manual
Once you have established in-band connectivity, you can change the IP information using
any of the following:
•
Terminal interface via the EIA-232 port
•
Terminal interface via telnet
•
SNMP-based management
•
Web-based management
1.
Use
IP Address
to specify the IP address of the interface. The factory default value is
169.254.100.100.
2.
Use
Subnet Mask
to enter the IP subnet mask for the interface. The factory default value is
255.255.0.0.
3.
Use
Default Gateway
to specify the default gateway for the IP interface. The factory default
value is 0.0.0.0
4.
Use
Locally Administered MAC Address
to configure a locally administered MAC address
for in-band connectivity instead of using the burned-in universally administered MAC
address. In addition to entering an address in this field, you must also set the MAC address
type to locally administered. Enter the address as twelve hexadecimal digits (6 bytes) with a
colon between each byte. Bit 1 of byte 0 must be set to a 1 and bit 0 to a 0, in other words,
byte 0 must have a value between x'40' and x'7F'.
5.
Use
MAC Address type
to specify whether the burned-in or the locally administered MAC
address should be used for in-band connectivity. The factory default is to use the burned-in
MAC address
6.
Use
Current Network Configuration Protocol
to specify what the switch should do
following power-up: transmit a Bootp request, transmit a DHCP request, or do nothing
(none). The factory default is DHCP.
7.
Use
DHCP Vendor Class Identifier
to enable DHCP VendorId option on the client.
8.
Use
DHCP Vendor Class Identifier String
to specify DHCP VendorId option string on the
client.
9.
Use
Management VLAN ID
to specify the management VLAN ID of the switch. It may be
configured to any value in the range of 1 - 4093. The management VLAN is used for
management of the switch. This field is configurable for administrative users and read-only
for other users.
The following table describes IPv4 Network Configuration information.
Table
2-9.
Field
Description
Burned In MAC Address
The burned-in MAC address used for in-band
connectivity if you choose not to configure a locally
administered address.
Содержание GSM7352S - ProSafe Switch - Stackable
Страница 8: ...8 Contents ProSafe Gigabit L3 Managed Stackable Switches Software Administration Manual Index ...
Страница 326: ...326 Chapter 4 Routing ProSafe Gigabit L3 Managed Stackable Switches Software Administration Manual ...
Страница 472: ...472 Chapter 6 Managing Device Security ProSafe Gigabit L3 Managed Stackable Switches Software Administration Manual ...
Страница 545: ...Chapter 6 Managing Device Security 545 ProSafe Gigabit L3 Managed Stackable Switches Software Administration Manual ...
Страница 547: ...Chapter 7 Monitoring the System 547 ProSafe Gigabit L3 Managed Stackable Switches Software Administration Manual ...
Страница 550: ...550 Chapter 7 Monitoring the System ProSafe Gigabit L3 Managed Stackable Switches Software Administration Manual ...
Страница 572: ...572 Chapter 7 Monitoring the System ProSafe Gigabit L3 Managed Stackable Switches Software Administration Manual ...
Страница 584: ...584 Chapter 8 Maintenance ProSafe Gigabit L3 Managed Stackable Switches Software Administration Manual ...
Страница 596: ...596 Chapter 8 Maintenance ProSafe Gigabit L3 Managed Stackable Switches Software Administration Manual ...
Страница 628: ...628 Index ProSafe Gigabit L3 Managed Stackable Switches Software Administration Manual Port VLAN ID 139 PVID 139 ...