Code
Indicates
HE
The system is awaiting connectivity with the E2800
controller and synchronizing with the SANtricity
operating system.
Note:
If this boot procedure does not progress past
this stage, check the connections between the two
controllers.
HC
The system is checking for existing StorageGRID
installation data.
HO
The StorageGRID Appliance Installer is running.
HA
StorageGRID is running.
E5700SG controller error codes
These codes represent error conditions that might be shown on the E5700SG controller as the appliance boots
up. Additional two-digit hexadecimal codes are displayed if specific low-level hardware errors occur. If any of
these codes persists for more than a second or two, or if you are unable to resolve the error by following one of
the prescribed troubleshooting procedures, contact technical support.
Code
Indicates
22
No master boot record found on any boot device.
23
The internal flash disk is not connected.
2A, 2B
Stuck bus, unable to read DIMM SPD data.
40
Invalid DIMMs.
41
Invalid DIMMs.
42
Memory test failed.
51
SPD reading failure.
92 to 96
PCI bus initialization.
A0 to A3
SATA drive initialization.
AB
Alternate boot code.
AE
Booting OS.