Module Replacement
51
6.3.3 Drive Carrier Module
Warning
Observe all conventional ESD precautions when handling SteelStore modules and components.
Avoid contact with backplane components and module connectors.
6.3.3.1
Removing a Drive Carrier
Important
Damage can occur to a drive if it is removed while spinning. If possible, use the operating system
to spin down the drives prior to removal. If this is not possible we recommend that you perform
all steps of the following procedure to make sure that the drive has stopped prior to removal.
1
Open the bezel to display the disks.
To release the bezel, press the tabs on each side of the bezel and pull toward you. The bezel remains
attached to the system on hinges.
2
If the anti-tamper lock has been activated, de-activate
it by inserting the key into its socket and rotating
it in a counterclockwise direction until the indicator is no longer visible in the aperture beside the key
(see section
). The key is a Torx T10 screwdriver provided with the appliance.
3
Release the carrier handle by pressing the latch in the handle towards the handle hinge (toward the front
of the appliance). See
Содержание SteelStore 30 Series
Страница 3: ......
Страница 9: ...NetApp SteelStore Cloud Integrated Storage xx30 Series Hardware Owner s Manual 4...
Страница 29: ...NetApp SteelStore Cloud Integrated Storage xx30 Series Hardware Owner s Manual 24...
Страница 47: ...NetApp SteelStore Cloud Integrated Storage xx30 Series Hardware Owner s Manual 42...
Страница 65: ...NetApp SteelStore Cloud Integrated Storage xx30 Series Hardware Owner s Manual 60...