![NetApp CN1610 Скачать руководство пользователя страница 392](http://html.mh-extra.com/html/netapp/cn1610/cn1610_cli-command-reference_1669922392.webp)
Chapter 5: Switching Commands
389
switchport
protected (Interface
Config)
Use this command to add an interface to a protected port group. The
groupid
parameter identifies the set of protected ports to which this interface is assigned.
You can only configure an interface as protected in one group.
Note
Port protection occurs within a single switch. Protected port configuration does
not affect traffic between ports on two different switches. No traffic forwarding is
possible between two protected ports.
no switchport
protected (Interface
Config)
Use this command to configure a port as unprotected. The
groupid
parameter
identifies the set of protected ports to which this interface is assigned.
show switchport
protected
This command displays the status of all the interfaces, including protected and
unprotected interfaces.
Default
unprotected
Format
switchport protected
groupid
Mode
Interface Config
Format
no switchport protected
groupid
Mode
Interface Config
Format
show switchport protected
groupid
Mode
◆
Privileged EXEC
◆
User EXEC
Term
Definition
Group ID
The number that identifies the protected port group.
Name
An optional name of the protected port group. The
name can be up to 32 alphanumeric characters long,
including blanks. The default is blank.
Содержание CN1610
Страница 3: ......
Страница 27: ...24 CLI Line Editing Conventions List available commands keywords or parameters Key Sequence Description ...
Страница 31: ...28 Accessing the CLI ...
Страница 309: ...306 Remote Monitoring Commands ...
Страница 473: ...470 Port Mirroring Commands 100 ...
Страница 487: ...484 DHCP L2 Relay Agent Commands Mode Privileged EXEC ...
Страница 607: ...604 IPv6 Management Commands ...