Chapter 5: Switching Commands
349
The following shows example CLI display output for the command.
(CN1610) >show spanning-tree summary
Spanning Tree Adminmode........... Enabled
Spanning Tree Version............. IEEE 802.1s
BPDU Guard Mode................... Disabled
BPDU Filter Mode.................. Disabled
Configuration Name................ ****
Configuration Revision Level...... ****
Format
show spanning-tree summary
Mode
◆
Privileged EXEC
◆
User EXEC
Term
Definition
Spanning Tree
Adminmode
Enabled or disabled.
Spanning Tree
Version
Version of 802.1 currently supported (IEEE 802.1s,
IEEE 802.1w, or IEEE 802.1d) based upon the Force
Protocol Version parameter.
BPDU Guard Mode
Enabled or disabled.
BPDU Filter Mode
Enabled or disabled.
Configuration Name
Identifier used to identify the configuration currently
being used.
Configuration
Revision Level
Identifier used to identify the configuration currently
being used.
Configuration Digest
Key
A generated Key used in the exchange of the
BPDUs.
Configuration Format
Selector
Specifies the version of the configuration format
being used in the exchange of BPDUs. The default
value is zero.
MST Instances
List of all multiple spanning tree instances
configured on the switch.
Содержание CN1610
Страница 3: ......
Страница 27: ...24 CLI Line Editing Conventions List available commands keywords or parameters Key Sequence Description ...
Страница 31: ...28 Accessing the CLI ...
Страница 309: ...306 Remote Monitoring Commands ...
Страница 473: ...470 Port Mirroring Commands 100 ...
Страница 487: ...484 DHCP L2 Relay Agent Commands Mode Privileged EXEC ...
Страница 607: ...604 IPv6 Management Commands ...