76
NetApp AltaVault Cloud Integrated Storage Installation and Service Guide for Physical Appliances
Beta Draft
System maintenance
Replacing a boot device in a controller
Removing the boot device from the controller
Before you begin, note the details about the image installed on your system before you do a clean shutdown of the
system for replacing the boot device. The same system image should be installed after boot device replacement.
Note:
You must connect to the console port of the AltaVault controller to carry out the tasks in this procedure.
To remove the boot device from the controller
1.
On the system console, type the following commands to note details of the operating system image that is installed
on your system. This same OS version and revision should be installed after the boot device replacement.
–
show info
to note the configuration details of your system
–
show images
command to view the
NetApp Release
,
Revision
,
Build date
,
Location
, and
Install Date
2.
Perform a clean system shutdown using the
reload halt
command.
3.
Power down your system and disconnect power from using the steps described in the procedure,
“Shutting down controllers” on page 60
4.
Remove the controller from the chassis using the steps described in the procedure,
“Replacing internal FRUs” on page 74
.
5.
If
you
are not already grounded, properly
ground yourself
.
6.
Locate the boot device holder using the FRU map on the CPU cover in the controller. The attention LED next to
the boot device holder is lit. The image below shows the boot device and holder.
Содержание AltaVault Cloud Integrated Storage 4.1