NetApp AFF A700s Скачать руководство пользователя страница 23

If the command fails because of a failed disk, physically disengage the failed disk, but leave the disk in
the slot until a replacement is received.

If the command fails because of an open CIFS session, check with the customer on how to close out
CIFS sessions.

Terminating CIFS can cause loss of data.

If the command fails because the partner is "not ready", wait 5 minutes for the NVMEMs to
synchronize.

If the command fails because of an NDMP, SnapMirror, or SnapVault process, disable the process. See
the appropriate Documentation Center for more information.

11. Once the giveback completes, check the failover and giveback status with the 

storage failover show

and 

`storage failover show

-giveback` commands.

Only the CFO aggregates (root aggregate and CFO style data aggregates) will be shown.

12. Move the console cable to the target controller.

13. If you are running ONTAP 9.5 and earlier, run the key-manager setup wizard:

a. Start the wizard using the 

security key-manager setup -nodenodename

 command, and then

enter the passphrase for onboard key management when prompted.

b. Enter the 

key-manager key show -detail

 command to see a detailed view of all keys stored in

the onboard key manager and verify that the 

Restored

 column = 

yes

 for all authentication keys.

If the 

Restored

 column = anything other than 

yes

, contact Customer Support.

c. Wait 10 minutes for the key to synchronize across the cluster.

14. If you are running ONTAP 9.6 or later:

a. Run the 

security key-manager onboard sync

 command and then enter the passphrase when

prompted.

b. Enter the 

security key-manager key query

 command to see a detailed view of all keys stored

in the onboard key manager and verify that the 

Restored

 column = 

yes/true

 for all authentication

keys.

If the 

Restored

 column = anything other than 

yes/true

, contact Customer Support.

c. Wait 10 minutes for the key to synchronize across the cluster.

15. Move the console cable to the partner controller.

16. Give back the target controller using the 

storage failover giveback -fromnode local

command.

17. Check the giveback status, 3 minutes after it reports complete, using the 

storage failover show

command.

If giveback is not complete after 20 minutes, contact Customer Support.

18. At the clustershell prompt, enter the 

net int show -is-home false

 command to list the logical

interfaces that are not on their home controller and port.

21

Содержание AFF A700s

Страница 1: ...edia ONTAP Systems NetApp June 13 2022 This PDF was generated from https docs netapp com us en ontap systems a700s bootmedia replace overview html on June 13 2022 Always check docs netapp com for the...

Страница 2: ...ard encryption keys AFF A700s 1 Shut down the controller AFF A700s 8 Replace the boot media AFF A700s 8 Transfer the boot image to the boot media AFF A700s 12 Boot the recovery image AFF A700s 17 Rest...

Страница 3: ...atus of the onboard encryption keys you must check the status of the impaired controller disable automatic giveback and check the version of ONTAP that is running If you have a cluster with more than...

Страница 4: ...ume show is encrypted true If any volumes are listed in the output NVE is configured and you need to verify the NVE configuration If no volumes are listed check whether NSE is configured 3 Check wheth...

Страница 5: ...ssphrase at the prompt If the passphrase cannot be provided contact mysupport netapp com Verify that the Restored column displays yes for all authentication key security key manager key show detail Go...

Страница 6: ...recover OKM Return to admin mode set priv admin Shut down the impaired controller b If the Restored column displays anything other than yes Run the key manager setup wizard security key manager setup...

Страница 7: ...ager types If the Key Manager type displays external and the Restored column displays yes it s safe to shut down the impaired controller If the Key Manager type displays onboard and the Restored colum...

Страница 8: ...arate file or your log file You ll need it in disaster scenarios where you might need to manually recover OKM g Return to admin mode set priv admin h You can safely shut down the controller Verify NSE...

Страница 9: ...c You can safely shut down the controller 3 If the Key Manager type displays onboard and the Restored column displays anything other than yes a Enter the onboard security key manager sync command secu...

Страница 10: ...your log file This command may not work if the boot device is corrupted or non functional Replace the boot media AFF A700s You must remove the controller module from the chassis open it and then repl...

Страница 11: ...ch Locking pin 1 Slide the controller module out of the chassis Make sure that you support the bottom of the controller module as you slide it out of the chassis 2 Place the controller module on a sta...

Страница 12: ...oot media by the lit LED near the boot media and then replace the boot media You need a Phillips head screwdriver to remove the screw that holds the boot media in place 1 If you are not already ground...

Страница 13: ...g the sides of the boot media gently rotate the boot media up and then pull the boot media straight out of the socket and set it aside 5 Align the edges of the replacement boot media with the boot med...

Страница 14: ...econd boot media You can install the system image to the replacement boot media using the image on second boot media installed in the controller module This is the primary method for transferring the...

Страница 15: ...l the way into the system until the controller module locking hooks begin to rise firmly push on the locking hooks to finish seating the controller module and then swing the locking hooks into the loc...

Страница 16: ...sing a USB flash drive This procedure should only be used if the secondary boot media restore failed or if the image tgz file is not found on the secondary boot media You must have a USB flash drive f...

Страница 17: ...roller module Make sure that you install the USB flash drive in the slot labeled for USB devices and not in the USB console port 7 Gently push the controller module all the way into the system until t...

Страница 18: ...eencryption support value bootarg keymanager support value bootarg onboard_keymanager value d Save the environment variables you changed with the savenv command e Confirm your changes using the printe...

Страница 19: ...essage perform a giveback from the healthy controller If your system is in Then An HA pair After the impaired controller is displaying the Waiting for giveback message perform a giveback from the heal...

Страница 20: ...d to reboot the controller No network connection a Press n when prompted to restore the backup configuration b Reboot the system when prompted by the system c Select the Update flash from backup confi...

Страница 21: ...NVE as needed AFF A700s Once environment variables are checked you must complete steps specific to systems that have Onboard Key Manager OKM NetApp Storage Encryption NSE or NetApp Volume Encryption...

Страница 22: ...G9iAAEAAAAEAAAAcAEAAAAAAADuD byAAAAACEAAAAAAAAA QAAAAAAAAABvOlH0AAAAAMh7qDLRyH1DBz12piVdy9ATSFMT0C0TlYFss4PDjTaV dzRYkLd1PhQLxAWJwOIyqSr8qY1SEBgm1IWgE5DLRqkiAAAAAAAAACgAAAAAAAAA 3WTh7gAAAAAAAAAAAAAAAA...

Страница 23: ...the key manager key show detail command to see a detailed view of all keys stored in the onboard key manager and verify that the Restored column yes for all authentication keys If the Restored column...

Страница 24: ...storage failover giveback fromnode local only cfo aggregates true local command If the command fails because of a failed disk physically disengage the failed disk but leave the disk in the slot until...

Страница 25: ...rt in an available state 11 If the Onboard Key Management is enabled a Use the security key manager key show detail to see a detailed view of all keys stored in the onboard key manager b Use the secur...

Страница 26: ...l prompt enter the net int show is home false command to list the logical interfaces that are not on their home controller and port If any interfaces are listed as false revert those interfaces back t...

Страница 27: ...oller using the storage failover giveback fromnode local command 13 Restore automatic giveback if you disabled it by using the storage failover modify node local auto giveback true command Return the...

Страница 28: ...WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE NetApp reserves the...

Отзывы: