Do not over-tighten the screw. Doing so might crack the boot media circuit board.
9. Reinstall the riser into the controller module.
10. Close the air duct:
a. Rotate the air duct downward.
b. Slide the air duct toward the risers until it clicks into place.
Transfer the boot image to the boot media - AFF A700s
You can install the system image to the replacement boot media using by using either the
image on second boot media installed in the controller module, the primary method to
restore the system image, or by transferring the boot image to the boot media using a
USB flash drive when the secondary boot media restore failed or if the image.tgz file is
not found on the secondary boot media.
Option 1: Transfer files to the boot media using backup recovery from the second
boot media
You can install the system image to the replacement boot media using the image on
second boot media installed in the controller module. This is the primary method for
transferring the boot media files to the replacement boot media in systems with two boot
media in the controller module.
The image on the secondary boot media must contain an
image.tgz
file and must not be reporting failures. If
image.tgz file is missing or the boot media reports failures, you cannot use this procedure. You must transfer
the boot image to the replacement boot media using the USB flash drive replacement procedure.
Steps
1. If you are not already grounded, properly ground yourself.
2. If you have not already done so, close the air duct:
a. Swing the air duct all the way down to the controller module.
b. Slide the air duct toward the risers until the locking tabs click into place.
c. Inspect the air duct to make sure that it is properly seated and locked into place.
12