Air duct locking tabs
Risers
Air duct
Step 2: Replace the boot media - AFF A700s
You must locate the failed boot media in the controller module by removing the middle
PCIe module on the controller module, locate the failed boot media by the lit LED near
the boot media, and then replace the boot media.
You need a Phillips head screwdriver to remove the screw that holds the boot media in place.
1. If you are not already grounded, properly ground yourself.
2. Locate the boot media:
a. Open the air duct, if needed.
b. If needed, remove Riser 2, the middle PCIe module, by unlocking the locking latch and then removing
the riser from the controller module.