NLC
‐
100SH
Installation
and
troubleshooting
70
2
Use
the
item
selectors
to
select
a
station
and
push
the
ENTER
button
to
start
the
test.
If
the
station
is
ok,
the
display
will
look
something
like
this:
In
this
case
the
station
is
pulling
a
current
of
238mA
to
keep
the
valve
open,
which
is
ok
since
this
is
typically
in
the
200
‐
400
mA
range.
Note:
The
number
before
the
slash
is
the
current
on
the
wire
before
trying
to
activate
the
station
‐
if
this
is
much
more
than
zero,
there
could
be
a
leak
somewhere.