28
FERTIKIT 3G
INSTALLATION MANUAL
ON-SITE PREPARATIONS
Description
Required proportions
D Main line - pipe diameter
d
Fertilizer/acid lines - pipe diameter:
•
32 mm (1¼") for dosing channels of up to 400 l/h (106 GPH)
•
40 mm (1½") for dosing channels of over 400 l/h (106 GPH)
X
1
Distance upstream from water meter
•
Pipe must be straight
10 x D
X
2
Distance downstream from water meter
•
Pipe must be straight
5 x D
X
3
Distance between inlet and outlet locations on the main line
•
“L” shape recommended for better mixing
Minimum 2 meter (6.5 feet)
X
4
Length of inlet and outlet pipes
Less than 3 meter (10 feet)
X
5
Length of fertilizers or acid lines
Less than 10 meter (33 feet)
H Elevation of the fertilizer/acid tanks
Higher than 30 cm (12")
Infrastructure required proportions
*
Hydraulic infrastructure preparation
The hydraulic infrastructure preparations should be performed according to the mode of the FertiKit™ to
be installed. Before performing the infrastructure installation, see the 'Typical setup' of the specific mode
of the FertiKit™ to be installed (see
).
Required proportions
To enable optimal operation of the FertiKit™, piping must be installed while maintaining the following
proportions.
*The minimum required distances between the inlet and the fertilizer/acid outlets of the
SP
mode on the
main line are not described in this table (see
).
FertiKit
TM
3G
d
X
1
X
2
X
3
X
4
X
5
H
D