NET NET145CL Скачать руководство пользователя страница 24

18 

                   

NET145LA/NET145CL User

’s Manual Rev1.0C

 

                                                       

               

 

© 2004 NET GmbH. All rights reserved 

 

Appendix A.  Compliant FG List 

 
 

 

 

Manufacturer 

Model 

Remark 

Mutech Corp 

MV1500 

 

Coreco Imaging 

X64-CL 

 

Euresys 

Multi 

 

Matrox Imaging 

Meteor-II / Digital 

 

National Instruments 

IMAQ-1422 

 

National Instruments 

IMAQ-1424 

 

NET New Electronic Technology GmbH  

Lerchenberg 7 
86923 Finning, Germany 
Tel: +49 8806 9234 0 
Fax: +49 8806 9234 77 
[email protected] 
www.net-gmbh.com 

NET Italia S.r.l.  

Via Carlo Pisacane, 9 
25128 Brescia, Italy 
Tel: +39 030 5237 163 
Fax: +39 030 5033 293 
[email protected]

 

www.net-italia.it 

NET USA, Inc.  

3037 45

th

 Street 

Highland IN 46322, USA 
Tel: +1 219 934 9042 
Fax: +1 219 934 9047 
[email protected]

 

www.net-usa-inc.com 

NET Japan Co., Ltd.  

2F Shin-Yokohama 214 Bldg. 
2-14-2 Shin-Yokohama, Kohoku-ku, 
Yokohama-shi, 222-0033, Japan 
Tel: +81 45 478 1020 
Fax: +81 45 476 2423 
[email protected]

 

www.net-japan.com 

Содержание NET145CL

Страница 1: ...om NET Italia S r l info net italia it www net italia it NET USA Inc info net usa inc com www net usa inc com NET Japan Co Ltd info net japan com www net japan com HIGH RESOLUTION DIGITAL AREA SCAN B...

Страница 2: ...tabilized PS may be used 2 2 2 5 Popular frame grabber 2 2 2 6 Lens 2 2 3 EXTERNAL DESCRIPTION 2 2 4 DIMENSIONS 6 2 5 IMAGER SPECTRAL SENSITIVITY CHARACTERISTICS 7 2 6 SETUP 7 2 6 1 Setup Configuratio...

Страница 3: ...N SOLUTIONS 17 9 TECHNICAL SUPPORT INFORMATION 17 Figure List FIGURE 1 PARTS DESCRIPTION 2 FIGURE 2 POWER AND TRIGGER CONNECTOR 3 FIGURE 3 SERIAL CONNECTOR 3 FIGURE 4 DATA CABLE CONNECTOR 4 FIGURE 5 N...

Страница 4: ...te the camera beyond the temperature range and avoid using the camera over 90 humidity Do not use unregulated power supply source Do not clean CCD faceplate with fingers or any hard objects other than...

Страница 5: ...or systems intended to surgically be implanted into the body or intended to support or sustain life Product and the company names in this document may be the trademarks and trade names of their respec...

Страница 6: ...vi NET145LA NET145CL User s Manual Rev1 0C 2004 NET GmbH All rights reserved Blank Page...

Страница 7: ...the commonly used RS 422 differential data bus RS 422 limits the frequency to the 20 MHz range However LVDS clock support is over 65MHz 66 MHz NSC 65 MHz TI and improves the signal transmission of ca...

Страница 8: ...cessories for setup option 2 2 1 RS 644 LVDS Cable or CameraLink Cable Should be the flexible twisted pair and overall shielded cable 2 2 2 RS 232 Cable 2 2 3 Power Cable 2 2 4 Power Supply PS low noi...

Страница 9: ...output connector Only for NET145LA Below is the connector for 15 Hz non interlaced video signal of 1 Vp p with Sync and RS 232C control Figure 3 Serial Connector 3 Pin Video 4 Pin 10V and 5Pin A GND...

Страница 10: ...ck output 2 HD Reference timing pulse output for line data 3 VD Reference timing pulse output for frame 4 EXT TRIG Random shutter trigger input Description for NET145LA Pin No Signal I O Pin No Signal...

Страница 11: ...GND 14 GND 2 TX0 15 TX0 3 TX1 16 TX1 4 TX2 17 TX2 5 TxClk 18 TxClk 6 TX3 19 TX3 7 SerTC 20 SerTC 8 SerTFG 21 SerTFG 9 CC1 22 CC1 10 NC 23 NC 11 NC 24 NC 12 NC 25 NC 13 GND 26 GND Normal Shutter Speed...

Страница 12: ...Size 50 W x 50 H x 76 L mm Weight approx 330gr 7 3 DC IN SYNC DATA OUT POWER 5 4 11 6 12 Ext sig REMOTE 4 3 10 2 1 8 9 2 6 1 5 1 Camera side connector HR10 7R 6PA Hirose 2 Cable side plug HR10A 7P 6S...

Страница 13: ...ure 6 Imager Spectral Sensitivity Characteristics 2 6 Setup 2 6 1 Setup Configuration Figure 7 System Configuration 2 6 2 Camera setup Cable connection procedure should be in the following order When...

Страница 14: ...he power cable from power supply to camera connector 3 1 Supply 12VDC power from the external DC power 3 2 For the power supply voltage supply the rated 12VDC If it fluctuates be sure to use the volta...

Страница 15: ...accumulation period after trigger input about 100ms after trigger is signaled 3 2 Vertical Sync Reset Vertical Sync Reset is only effective in Random Shutter Mode 3 2 1 When reset After the trigger s...

Страница 16: ...ually not important The scheme is conceptually simple The transfer of an image starts when FVAL VD goes low During this time LVAL VD goes from high to low thus indicating the transfer of the n th line...

Страница 17: ...Pixel Clock 1CLK 35nS Pixel Clock Digital Data Pixel Clock 28 6364MHz B The Condition after Input Random Trigger Random Trigger VD Strobe Pulse Exposure Time Video Out Shutter Image CCD Exposure Peri...

Страница 18: ...is necessary to provide a text start character control code STX at the beginning of each command and a text end character control code ETX at the end All the alphabetic characters of each command shou...

Страница 19: ...ec 04 2 1 60sec 04 3 1 120sec 04 4 1 500sec 04 5 1 1000sec 04 6 1 2000sec 04 7 1 3000sec 04 8 1 4000sec 04 9 1 8000sec GAIN 06 0 XX ADC gain control 00 0dB FF 24dB default 64 XX 0x00 0xFF Fine Draft m...

Страница 20: ...g condition Initial setting condition means Factory setting condition 6 SAVE LOAD Available memorized and call preset setting condition This command can memorize camera setting condition max 6 modes a...

Страница 21: ...A The bandwidth of the Meteor II Digital is not sufficient for the full speed mode of NET145LA All the other cameras may be used in Full Speed mode Please note that the Meteor II DIG works with Window...

Страница 22: ...pixel 1392 H x 1040 V Pixel Size 6 45 m x 6 45 m Image Area 10 2 H x 8 30 V mm Scanning System Progressive Scan Frame Rate 15fps full pixel read out Shutter Speed 20 s 66ms Aspect Ratio 4 3 Lens Mount...

Страница 23: ...s etc 9 Technical Support Information If you need technical assistance please do not hesitate to contact NET GmbH Technical Support NET New Electronic Technology GmbH Lerchenberg 7 86923 Finning Germa...

Страница 24: ...23 Finning Germany Tel 49 8806 9234 0 Fax 49 8806 9234 77 info net gmbh com www net gmbh com NET Italia S r l Via Carlo Pisacane 9 25128 Brescia Italy Tel 39 030 5237 163 Fax 39 030 5033 293 info net...

Отзывы: