3. Repeat with the variable of interest to view the syntax for all commands avail-
able from the CLI. For more information on CLI commands, see Appendix B.
Mounting the iTap
The iTap is designed for rack mounting in a two-slot, 19-inch panel. The mounting
panel occupies one rack unit.
To rack mount the iTap:
1. Attach the two-slot panel to your rack using the attached thumbscrews.
2. Slide the iTap into one of the slots and secure with the attached thumbscrews.
3. Make sure that the rack is properly grounded.
The iTap can also be placed on a surface using the pads supplied with the iTap.
Connecting the Management Port
To use the remote interfaces you must connect the Management Port to the
network.
Figure 10:
Connecting the Management Port
To connect the iTap Management Port:
1. Connect a CAT5 cable to the Manangement Port as shown in Figure 10.
2. Connect the other end of the cable to a network switch or hub.
Management
Port
RS232
To network switch or hub