26
•
Maintenance
Element Manager User’s Manual Nimbra OneSerie
©2006 Net Insight AB, All rights reserved
Setting of system parameters
The System page contains system parameters and a control for software restart
of the unit.
The configurable parameters are:
Parameter name
Description
Type
Restart and halt of
system
Buttons and text box for halt or soft
restart of the system.
Opt
System name
The name of the unit, to be used
instead of the IP address, for easier
recognition in the web page.
Opt
Contact
E.g. the name or the e-mail address
of the contact person for the unit.
Rec
Location
Optional description of the location
of the unit.
Rec
Name server
The IP address of the DNS (Domain
Name Server) server. Translates the
name to an IP-address.
Rec
NTP Server
The IP address of the NTP (Network
Timing Protocol) server.
Rec
Event and Alarm log
parameters
Settings for the parameters to be
logged by the system.
The Event log in the network
element should be large enough to
hold event for at least a couple of
minutes. A rule-of-thumb is 2.5 times
the number of expected connections
originating or terminating on the
node, but not less than 50.
Rec
Type definitions:
Man – mandatory, Rec – recommended, Opt – optional
1.
Navigate to the Maintenance|System page, Figure 16, will appear.
Figure 16. The Maintenance, System page
2.
Enter the System name, the name of the Contact person and the
Location. Enter the address of the NTP Server.