background image

5 of 24

2.1.3. Summary of rules

We shall now provide a summary of the rules that
should be followed when building a chimney:

Use resistant and non-combus�ble materials
for the connec�on between the appliance and
the chimney, which are protected if possible
against rust (enamelled steel, stainless steel, …)

Choose the most ver�cal route possible.

Do not connect several devices to the same
chimney.

The conduit should not come to an end near
buildings and must be higher than the nearest
obstacle if there is another building nearby.

The internal walls must be perfectly smooth
and free from obstacles.

Avoid bo�lenecks where pipes join the brick
chimney.

Ensure that the joints of the pipes are well
sealed to avoid air entering through cracks.

2.2. Installa�on of the stove.

1. Posi�on the unit no closer than the minimum

clearances to combus�ble materials (see safety
chapter). Re-posi�on unit if necessary, being careful
not to move closer than the minimum clearances.

2. Posi�on the unit on the floor at the proper

clearances. If the floor is made of combus�ble
material (for example, parquet) it must be protected
with a slab of fireproof material, placed under the
stove and around it. The size should be such that it
protrudes from the appliance: 20 cm back and sides
and 50 cm front.

3. Install the stove to the fireplace, sealing it properly.
4. The stove can never be connected to air ducts or a

ven�la�on system.

5. Appropriate firebreaks, firewalls must be installed

when a sec�on of the chimney passes through
floors and/or ceilings. The insula�on will be at least
50 mm thick from the flue to the structure. It is
necessary to protect the walls with wall protectors
when the chimney is not at the indicated sage
distance and damage may occur. (See Fig. 2.).

FIG :2

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE

SERVING ANOTHER APPLIANCE.

Fig. 3.- Chimney connec�on in a fireplace.

Thermal Insulation

Chimney pipe

Ceiling

Metal Fitting

Flue liner

Total height
minimum of
4.5 m

Sufficient clearance, also for
maintenance and air circula�on

Cowl

Liner to top of
termina�on and
insulated

Flue liner
support collar

Weatherproof
capping and pot

Sound chimney
brick work

Flexible to single
wall adaptor

Register plate,
posi�oned as low
as possible to aid
convec�on

Access for
cleaning

Содержание M43

Страница 1: ...NSTALLATION DE SERVICE ET D ENTRETIEN INSTRUCTIES VOOR GEBRUIK EN INSTALLATIE ISTRUZIONI PER L INSTALLAZIONE L USO E LA MANUTENZIONE INSTALLATION USE AND MAINTENANCE INSTRUCTIONS INSTRUCCIONES PARA INSTALACIÓN USO Y MANTENIMIENTO ...

Страница 2: ...2 of 24 ...

Страница 3: ...use petrol or other flammable vapours and liquids in the vicinity of this or any other heang appliance Do not use aerosol sprays near the stove when the stove is alight Do not burn anything but natural wood or approved smokeless coals on this appliance Advise all persons as to the stove s high surface temperatures If it is possible for children or infirm adults to come into contact with the stove ...

Страница 4: ... stove Consult your local building department for chimney code requirements A masonry chimney should have a code approved liner This liner must not have broken or missing pieces Some non code masonry chimneys may be brought up to code by being relined Consult your dealer or qualified chimney sweep Factory built metal chimneys should also be inspected first for creosote deposits which should be rem...

Страница 5: ...oor is made of combus ble material for example parquet it must be protected with a slab of fireproof material placed under the stove and around it The size should be such that it protrudes from the appliance 20 cm back and sides and 50 cm front 3 Install the stove to the fireplace sealing it properly 4 The stove can never be connected to air ducts or a ven la on system 5 Appropriate firebreaks fir...

Страница 6: ...r possible design your installa on so that the wall connector does not pass through a combus ble wall If you are considering a wall pass through in your installa on check with your building inspector before you begin Also check with the chimney connector manufacturer for any specific requirements Accessories are available for use as wall pass throughs If using one of these make sure it has been te...

Страница 7: ...tem uses a balance of preheated primary air secondary air and natural flue dra in a process of combus on and post combus on to obtain extremely high efficiency and total controllability of the fire The Woodbox stoves are equipped with a variable flap mechanism to control the air intake with precision according to the type of combus on and the desired tempo of the fire The controls allow you to ope...

Страница 8: ... once the combus on chamber has increased its temperature will allow the gases to recirculate through the catalyst where a chemical reac on will occur in which the vast majority of the emissions generated during the combus on process will disappear Fig 8 By pass close Fig 9 By pass open Fig 10 Op onal stove starter sec on with draught control By pass Catalyst Rear flap for adjus ng the minimum air...

Страница 9: ...he stove when adjus ng the controls Burn rate knob Governs the amount of air entering the stove Allows you to control the tempo of the fire As the knob is rotated counter clockwise the cam progressively opens the air flap to increase the amount of air entering the stove Low opera on At low se ng the flap is barely open as to reduce the intake of air Normal opera on At normal se ng the flap is abou...

Страница 10: ...combus on Ligh ng Burn Type Lever in mid posi on Providing maximum air above and below grate for igni on Wood Burn Type Lever raised posi on A Providing top air for wood burning 3 3 1 Burn types 3 3 2 Burn rates En Ligh ng Wood Minimum Maximum 3 3 3 Examples of air se ngs Fig 11 Ligh ng and reloading Fig 12 Normal running wood ...

Страница 11: ...ed flue dra Minimum air screw open this is the factory se ng suitable for a normal flue draught Minimum air screw closed or nearly closed in the case of an excessively strong flue draught 3 3 5 Remote Control op onal This stove has the op on of remote control Fi ng the remote control motor At the rear of the appliance you will see the motor fi ng bracket This incorporates a magnet and the mechanis...

Страница 12: ... place the valve open 3 4 LIGHTING IMPORTANT The surface of your device is protected by a coat of special anti heat paint that resists high temperatures When lighting the fireplace for the first few times the said paint may emit some fumes This is normal and is due to the evaporation of certain components of the paint while it adapts to the heat We therefore recommend ventilating the room until th...

Страница 13: ...towards the front of the stove spreading them evenly If there are logs only par ally burned rake these to the front of stove Add fuel If the fire is almost depleted and a full load of cordwood is added it may be necessary to leave the Burn Rate Knob on the high se ng for a while to re establish a lively fire Once the fuel is burning at a brisk rate slide the Burn Type Lever back to Posi on A and t...

Страница 14: ...ashed ashore from the sea as fuel The salt contained in it will react in the combus on process and release acid that will damage the iron and steel Your stove is approved for use with wood only Do not burn par cle board scraps or pressed logs using bonding agents because they can produce condi ons which will deteriorate metal Green or uncured wood does not work well as fuel and can cause increased...

Страница 15: ...uide to this is when the new charge of fuel is burning vigorously Storage me for wood Wood supplied in ready cut lengths stored immediately under a ven lated shelter dries quicker than wood stocked in high piles Quarters split wood dry quicker than round logs Wood which is too small to split must be drained by removing some of the bark Round logs le in the open for more than a year end up ro en Th...

Страница 16: ...her objects Keep all furniture and drapery a minimum of one metre from the stove Clean the stoves surface using light strokes of a real bristle paint brush Stoves with a cast black finish should never be cleaned with a cloth as the texture of the paint will abrade and collect lint from the cloth which will be almost impossible to remove Stoves with an enamel finish should be cleaned with a damp cl...

Страница 17: ... en if the use of the stove or the fuel make it necessary For cleaning purposes the baffle plates can be removed without any tools This gives access to the cleaning flap of the smoke flue and it is even possible to reach the flue outlet It also allows the removal of the catalyst box on the TruHybrid variants for examina on and sweeping of the flue Ashes shall be removed and disposed of in a steel ...

Страница 18: ...18 of 24 6 INSTALLATION SYSTÈME TRUHYBRID INSTALLATIE TRUHYBRID SYSTEEM INSTALAZIONE SISTEMA TRUHYBRID TRUHYBRID SYSTEM INSTALLATION INSTALACIÓN SISTEMA TRUHYBRID 1 2 3 7 5 4 6 ...

Страница 19: ...19 of 24 7 8 9 10 ...

Страница 20: ...20 of 24 7 DIMENSIONS ...

Страница 21: ... 13 O2 mg m3 82 OGC concentration 13 O2 mg m3 69 Efficiency 86 Smoke collar Ø int mm 180 Metal chimney Ø int mm 180 Recommended chimney height m 5 6 Recommended draw Pa 12 Smoke outlet Vertical Weight Kg 197 Values obtained according to UNE EN 13240 with the TruHybrid System The TruHybrid system is only available for vertical smoke outlets ...

Страница 22: ...22 of 24 ...

Страница 23: ...23 of 24 ...

Страница 24: ...24 of 24 SOTO DE LA MARINA CANTABRIA Apdo de correos 208 SANTANDER C07100DC676_1 ED 04 2020 ...

Отзывы: