background image

USER SETTINGS 

(User Settings can be programmed by the User at any time without entering Program Mode)  

 
Assigning a PIN to a CARD

 

 
If the system is programmed for access is to be granted with “Card and PIN” (Programming Option 32 set) a PIN 
for each Card must be assigned using this option. (The Factory Default when cards are first programmed into 
the system is PIN 1234) 

Press  * 

 

Present the Card 

to the Reader  

 

Enter Old PIN 

(Default 1234) 

 

 

Enter 

NEW PIN 

 

 

Repeat the 
NEW PIN

 

 

 

 
 
Assigning a PIN to a ID Number

 

 
This option also assigns a PIN to a Card, but if the card is unavailable you can assign it to the User’s ID Number 
(Memory slot Number)  

Press  * 

 

Enter the ID 

Number the PIN 

will be assigned to 

 

 

Enter 

Old PIN 

 

 

Enter 

New PIN 

 

 

Repeat the 

NEW PIN

 

 

 

 

OPERATION

 

   Unlocking the Door By Card OR PIN

       .                   

If the Door Access Control Setting (Section 6) is programmed to “Card or PIN”, access will be granted by 
presenting a valid Card to the Reader or by entering a valid PIN 

 
Either                                                                         OR 

If successful, the LED will flash Green and the Relay will activate for the Unlock time  

 If unsuccessful, the S2 will sound 3 Beeps and the likely cause will be a non valid Card (unprogrammed or 

incorrectly programmed) or incorrect PIN entry (refer to Programming Section 3, “Adding Users”) 

If  a Card is presented and the LED glows steady S2 is waiting for a PIN to be entered. If this is not intended refer 
to Programming Section 6 “Door Access Control Settings” and select the correct Access Setting 

 

 

 

 

Present Card to Reader 

Enter 4 Digit PIN followed by  # 

Содержание S2

Страница 1: ...1 S2 Metal Waterproof Access Control Unit Installation and User Manual Ness Part No 101 082 ...

Страница 2: ...er is granted access or can interface to 3rd party products via its 26 Bit Wiegand output Installation Drill a hole in the wall to match the location of the cable at the rear of the S2 or mount a suitable wall mount junction box Thread the cable through cable hole and connect related cables Take care to insulate the unused cables to prevent shorting Fix the back cover to the wall or distribution b...

Страница 3: ...one second and then glow steady Red while S2 awaits Program Option Commands To Exit Program Mode press If no keys are pressed for 60 seconds S2 will automatically exit Program Mode and resume Operation Mode The following options can be accessed and programmed in Program Mode 2 Changing the Master Code Master Code must be 6 digits long Can only be done in Master Programming Mode Press 0 The LED wil...

Страница 4: ...n Press to end If more Users are to be added repeat the process for each User Press 1 Enter ID No 1 Enter PIN 1 Enter ID No 2 Enter PIN 2 All PIN numbers must be 4 Digits of any number combination however they must not be 1234 3 4 Adding Card Users Sequentially Multiple Users can be added sequentially as either a Card or Pin Press 1 Present Card 1 to the Reader Enter ID No 1 Present Card 2 to the ...

Страница 5: ... to be deleted Enter ID Number of the next User to be deleted 4 3 Deleting ALL users Press 2 The LED will glow Orange Press 0000 followed by the button The LED will then flash Green confirming that all Users have been deleted Press 2 0000 4 4 Deleting Users using the Delete User Master Card Cards may be deleted anytime without entering Programming mode using the Delete User Master Card that comes ...

Страница 6: ...nput When enabled If the door is opened normally but not closed within 1 minute the buzzer will sound for 1 minute If the door is forced open opened by an unauthorized user the buzzer and alarm output will be activated 9 Security Mode Settings for Invalid Access Attempts Can only be done in Master Programming Mode Three options are provided for programming Keypad Lockout Alarm Output in the event ...

Страница 7: ...uired Site Code 0 255 Site Code must be between 0 and 255 11 Setting the Address of the Reader Default 0 Can only be done in Master Programming Mode When using S2 with security equipment that supports addressable readers such as Ness D8XD 16XD Panels Ness 6DA controllers etc it may be necessary to set the address of the reader When programmed to Address 0 Default the Wiegand Output uses standard 2...

Страница 8: ... Number the PIN will be assigned to Enter Old PIN Enter New PIN Repeat the NEW PIN OPERATION Unlocking the Door By Card OR PIN If the Door Access Control Setting Section 6 is programmed to Card or PIN access will be granted by presenting a valid Card to the Reader or by entering a valid PIN Either OR If successful the LED will flash Green and the Relay will activate for the Unlock time If unsucces...

Страница 9: ...lay will activate for the unlock period If no PIN is entered within 5 seconds S2 will time out and the LED will return to its normal red Flashing mode AND S2 will sound 3 beeps if the entered PIN is invalid or incorrect Resetting Restoring an Alarm If an Alarm occurs for any reason e g Door Forced Open or Open Too Long it can be reset by presenting A valid card to the Reader or by entering the Mas...

Страница 10: ...any External EM HID IC readers with Wiegand 26 bit Output Connect High Power Alarm External Current of the Alarm 3A Dimensions 135mm x 57mm x 25mm Operating Voltage DC 12 24V AC 12 18V Current Idle 35mA Active 80mA Card Reading Distance 3 6 cm Operating Temperature 40 60 Deg C Lock Output Load 2A Max Head Office 4 167 Prospect Hwy Seven Hills NSW Australia Phone 61 2 8825 9222 email ness ness com ...

Отзывы: