H O W T O P R O G R A M E N T RY A N D E X I T T I M E S
Your L-8 Control Panel will have zone(s)
which are called Entry/Exit zones. These are
the zone(s) which you normally enter and
leave your premises by. To allow you to do
so without causing a false alarm, there is
an Exit Time which the Control Panel gives
you to depart your premises after you Arm
the Panel. There are 2 separate entry times
which the Control Panel gives you to Disarm
the Panel when you have entered the prem-
ises before an alarm occurs.
Your installer may have programmed differ-
ent zones with a long entry time and a short
entry time zone. (A long and short entry
time is useful if you enter by a garage or a
front door).
TO PROGRAM YOU MUST KNOW A FEW RULES:
Exit time can be programmed from 1 to 99
seconds in 1 second increments.
Entry 1 time can be programmed from 1 to
99 seconds in 1 second increments.
Entry 2 time can be programmed from 10 to
990 seconds in 10 second increments,
Each one of the timers has a 2 digit program
option number.
The current timer value is displayed by the
L-8 when you select a timer option. The
value is displayed by flashing out the value
on the numeric zone lights 1 to 8, 9= battery
and 0= mains at 1 second intervals.
When you change the timer value the new
value is displayed as above. The option
numbers are as follows;
Programming always follows this sequence;
Entry 1 timer = Option 26
Entry 2 timer = Option 27
Exit time = Option 28
To view a timer, press…
2 digit option
To change a timer , press…
New Value
New Value
Displayed
Program
..Enter..
..Enter..
Value
displayed