25
ness Guardpost installation & Programming
progrAMMINg optIoNS SUMMAry (ALL)
Program
option
name
SmS
Program
option no.
(xx)
value (yy)
Description
Default
Page
no.
KEY 1-23
N/A
KEY, DURESS, MEDIC,
BELL, NO PAN, ERASE
Options for learning radio keys
None
18
SENS 1
N/A
ALARM, HOME, HOME 2,
FIRE, CHIME, ACHIME,
HCHIME, H2CHIM,
SILENT, EXCLUD
Options for the onboard sensor
ALARM
SENS 2-23
N/A
ALARM, HOME, HOME 2,
FIRE, CHIME, ACHIME,
HCHIME, H2CHIM,
SILENT, EXCLUD
Options for the optional radio devices 2-23
ALARM
RANGE
01
00, 01
Onboard PIR range. 00 = Low, 01 = High
LOW
19
PULSE
02
01, 02, 03, 04
Onboard PIR pulse count.
1 PULS
SIGNAL
N/A
–
Radio devices signal strength check
–
RADJAM
N/A
ON, OFF, SILENT
Radio jamming alarm
OFF
RADSUB
N/A
ON, OFF
Radio message substitution alarm
OFF
SUPVIS
03
00, 01, 04, 08, 16, 24
Supervision time in hours. 00 = Supervision disabled
OFF
LOKOUT
04
00
Alarm Lockout. 00 = Disabled, 01 = Enabled
OFF
20
ENTRY
05
05, 10, 15, 20, 25, 30
Entry delay in seconds
5 sec
EXIT
06
05, 10, 15, 20, 25, 30, 35,
40, 45, 50, 55, 60
Exit delay in seconds
5 sec
SIREN
07
01, 02, 03, 04, 05
Siren time in minutes
5 min
CHIRPS
08
00, 01
External Siren Chirps. 00 = Disabled, 01 = Enabled
ON
V-ARM
N/A
ON, OFF
Voice annunciation for arming/disarming
ON
V-ALRM
N/A
ON, OFF
Voice annunciation for alarms
ON
21
V-BATT
N/A
ON, OFF
Voice annunciation for battery alarms
ON
V-FALT
N/A
ON, OFF
Voice annunciation for system faults
ON
V-DEMO
N/A
–
Not available in this version
OPEN
09
00, 01, 02, 03
Open Close Reports. 00 = Disabled, 01 = ON, 02 = RESTOR,
03 = RES+OC
OFF
LOWBAT
10
00, 01, 02, 03
Low Battery Reporting. 00 = NONE, 01 = MAIN, 02 =
SENSOR, 03 = ALL
NONE
CLIENT
CL1
Up to 4 digits
Client account number
0000
PHONE 1
PH1
Up to 20 digits
Telephone No. 1 for reporting alarms by CID, SMS or AUD
none
22
PHONE 2
PH2
Up to 20 digits
Telephone No. 2 for reporting alarms by CID, SMS or AUD
none
GSM SG
N/A
–
Indicates GSM signal strength 0=no signal, 9=best signal
ABORT
11
00, 05, 10, 15, 20, 25, 30,
35, 40, 45, 50, 55, 60
Dialler Abort delay in seconds.
5 sec
MEDIC
12
00, 05, 10, 15, 20, 25, 30,
35, 40, 45, 50, 55, 60
Medical Key Abort delay in seconds.
20 sec
23
T-CALL
13
00, 01, 07, 14, 30
Test Call interval in days. 00=Test Calls disabled
OFF
(7 DAY when
dialler = CID)
DIALER
14
00, 01, 02
Dialler reporting format
00 = Contact ID (CID), 01 = SMS, 02 = Audible
CID
POWER
15
01, 02, 03, 04, 05, 06,
07, 08
01 = BATT, 02 = BAT-30, 03 = BAT-1H, 04 = BAT-2H, 05 =
AC-ON, 06 = SLR-30, 07 = SLR-1H, 08 = SLR-2H
BATT
24
DEFALT
N/A
ALL, OPTION, KEY, SENSOR
Reset factory defaults
N/A
P-EXIT
N/A
–
Press the ON button on your radio key to exit program mode.
N/A
Only
available by
SMS
V
Request current programmed options. Guardpost replies with
the current values of all programmed options
N/A
–
Options numbers marked “N/A” are not available for programming by SMS.
See page 28 for a version of this options summary showing only SMS programming options.