I
S100 Quick Set-Up Guide
07/07|V1.0 890-377
2007-2010© Ness Security Products. All rights reserved.
3
Output Connections
All Aux Output connections are used for general purpose controls.
Note:
Relay contacts are rated for 30VDC @ 2Amps.
Input Connections
Input connections are used for a combination of specific functions such as Request-to-Exit (REX), Door
monitor, etc. They can also be used as general purpose monitoring. Connect one side of the switch or
contact to the
+
(plus) lead and the other to the
–
(minus) lead.
The default REX switch configuration is normally open (NO) unsupervised (no EOL resistors), while the
default door switch (DS) configuration is Normally Closed (NC), unsupervised (no EOL resistors). All other
input points are defaulted for NO switches and are unsupervised (no EOL resistors).
Any input can be configured as a supervised input. They can be configured for resistors of 1K – 4K Ohm.
The setup of supervised inputs is done during configuration of the Modules in the IS100 software.
Please refer to the following examples