101-092 25
FINGER007
–
Version 4.0
IDTeck – FINGER007 FINGERPRINT & PROXIMITY READER
•
The [PW] is for password input the password is needed to access doors when the controller is operating
in RF+Finger(P/W) or RF+P/W+Finger mode. But regardless of the operating mode, it is necessary to
input a password when registering.
•
The [TS] is Time Schedule code (00-10). [TS] is the Time Schedule for the Main Reader, Extra Reader.
When you present the card to Reader then the cardholder is only allowed the access of the door during
the Time Schedule code entered to TS__ . To control the accessible Time Schedule for each cardholder,
you must setup the Time schedules first and enter the Time Schedule code here. If you want to access the
door anytime for the cardholder then enter default Time Schedule code '00' for the value.
•
The [RD] is reader usage codes for the cardholder. If you put ‘1’ for RD then Main Reader is accessible
and if you put ‘0’ for RD then the cardholder can not access through the Main and Extra Reader, and
FINGER007
generates an error message “Access Door Error!” and displays on the LCD. To get access
through all Readers, you have to input “3” value for RD.
•
The [FP] is for using fingerprint. If “1” is entered for the value, the user has to register fingerprint. And
the user certification of fingerprint in RF+Finger(P/W) and RF+P/W+Finger mode. If “0” is entered for
the value, fingerprint substitute by password.
8. OPERATION
8.1 NORMAL OPERATION
Power ON
When the Power is applied to
FINGER007
, the RED LED is turned on.
Registered Card Reading
When a registered card (or PIN) is read, the Door(Relay 1) will open for 3 seconds(Defaults) with the
Green LED on.
Exit Button
To request for exit from the inside, an Exit Button(or Extra Reader) can be used. The Door(Relay 1) will
open for 3 seconds(Defaults) with the GREEN LED on.
Alarms (unregistered/password/fingerprint/time schedule/door ERROR)
When an unregistered card is read, wrong password is input, wrong fingerprint is input, over the time
schedule, and access wrong door, the access is denied and the alarm(Relay 2) will be activated for 3
seconds(Defaults) with RED LED on.
Содержание Finger007
Страница 36: ...101 092 36 FINGER007 Version 4 0 IDTeck FINGER007 FINGERPRINT PROXIMITY READER 9 2 SETUP MENU F2 ...
Страница 59: ...101 092 59 FINGER007 Version 4 0 IDTeck FINGER007 FINGERPRINT PROXIMITY READER ...
Страница 60: ...101 092 60 FINGER007 Version 4 0 IDTeck FINGER007 FINGERPRINT PROXIMITY READER TEMPLATE ...
Страница 61: ...101 092 61 FINGER007 Version 4 0 IDTeck FINGER007 FINGERPRINT PROXIMITY READER ...