The E-CODER)R450
i
Config Email provides feedback on the RSSI values between the
E-CODER)R450
i
and the collector following MIU activation. Depending on the RSSI values
recorded, the system indicates the following values:
l
Pass.
l
Marginal.
l
Fail.
RSSI values in the Pass range are required for both the Uplink and the Downlink to ensure
full, two-way capabilities of the E-CODER)R450
i
as part of the R450 System. For more
information, see the next two tables.
RSSI Description
RSSI Values
Result in Performance
Pass
RSSI ≥ –105
Reliable daily readings and profile data.
Marginal
–115 < + RSSI < –105
Occasional missed daily readings and
profile data.
Fail
RSSI < –115
Poor readings performance.
Table 5 – Collector RSSI Uplink
RSS Description
RSSI Values
Result in Performance
Pass
RSSI ≥ –95
Full capability.
Marginal
–105 ≤ RSSI < –95
Occasional two-way capability, not
reliable.
Fail
RSSI < –105
E-CODER)R450
i
not capable of two-way
communications.
Table
6
–
E-CODER
®
)R450
i™
RSSI
Downlink
E-CODER
®
)R450
i™
Installation and Maintenance Guide
13
Chapter
5:
Activating
and
Testing
the
E-CODER
®
)R450
i
™
Содержание E-CODER) R450i
Страница 1: ...E CODER R450i Installation and Maintenance Guide...
Страница 2: ......
Страница 3: ...E CODER R450i Installation and Maintenance Guide...
Страница 10: ...This page intentionally left blank ix E CODER R450i Installation and Maintenance Guide Figures...
Страница 12: ...This page intentionally left blank xi E CODER R450i Installation and Maintenance Guide Tables...
Страница 39: ......