background image

Nuvo-2000+ Series User’s Manual

Copyright © 2013 Neousys Technology Inc. All Right Reserved.

Page 27 of 78

2.3.11 Optional Isolated DIO

Nuvo-2000+ offers an option of on-board 2500Vrms isolated DIO for extending application

range. This option provides 8 channels of isolated digital input and 8 channels of isolated

digital output via a on-board 2x13 pins box header. Neousys also provides a flat cable and

DSub 25-pin connector to allow front-panel access for the DIO function.

Содержание Nuvo-2021+

Страница 1: ...ies User s Manual Copyright 2013 Neousys Technology Inc All Right Reserved Page 1 of 78 Neousys Technology Inc Nuvo 2000 Series Intel Atom D525 Fanless Controller User s Manual Rev A1 Published Septem...

Страница 2: ...ront Panel I O Functions 13 2 2 1 Power Button 13 2 2 2 Reset Button 13 2 2 3 LED Indicators 14 2 2 4 USB Connectors 14 2 2 5 Gigabit Ethernet Port 15 2 2 6 Audio Jacks 15 2 2 7 VGA Connector 16 2 2 8...

Страница 3: ...nect DC power via the DC jack 52 3 8 Power on your Nuvo 2000 53 3 8 1 Power on Nuvo 2000 using the power button on the front panel 53 3 8 2 Power on Nuvo 2000 using an external latched switch AT mode...

Страница 4: ...nstall WDT and DIO Library 70 A 2 Function Reference 72 InitWDT 72 SetWDT 72 StartWDT 73 ResetWDT 73 StopWDT 73 Appendix B Using Isolated DIO 74 B 1 Wiring for Isolated DIO 74 B 2 Install WDT and DIO...

Страница 5: ...ates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipm...

Страница 6: ...ing Intel Atom D525 1 8GHz dual core processor Nuvo 2000 accommodates three PCI PCIe cards and two 2 5 hard drives in its shoe box size More than that it provides versatile I O interfaces such as COM...

Страница 7: ...USB 2 0 ports Audio 1x Mic in and 1x Speaker out Internal I O Interface Video Port 1x Optional 2nd VGA output via flat cable supporting 1366 x 768 resolution Serial Port 2x RS 232 COM3 COM4 Parallel...

Страница 8: ...11ms Duration w SSD according to IEC60068 2 27 EMC CE FCC Class A according to EN 55022 EN 55024 Full loading power consumption is measured with 2GB DDR3 memory and one 2 5 SATA HDD installed under t...

Страница 9: ...rnal I O Interface Video Port 1x Optional 2 nd VGA output via flat cable supporting 1366 x 768 resolution Serial Port 2x RS 232 COM3 COM4 Parallel Port 1x Parallel port Isolated DIO Optional 8 CH isol...

Страница 10: ...to IEC60068 2 27 EMC CE FCC Class A according to EN 55022 EN 55024 Full loading power consumption is measured with 2GB DDR3 memory and one 2 5 SATA HDD installed under the following conditions 100 lo...

Страница 11: ...o of Channel 8 CH Isolated Digital Input Channels Logic Level Logic High 5 to 24V Logic Low 0 to 1 5V Isolated Voltage 2500 Vrms Input Resistance 2 4k Isolated Digital Output No of Channel 8 CH Isolat...

Страница 12: ...item is missing or damaged please contact your local dealer or Neousys Technology Inc for further assistance Item Description Qty 1 Nuvo 2030 or Nuvo 2021 fanless controller According to the configur...

Страница 13: ...s lighted up To turn off the Nuvo 2000 you can either issue a shutdown command in OS or just simply press the power button In case of system halts you can press and hold the power button for 5 seconds...

Страница 14: ...USB ports on the front panel By BIOS default these USB ports are operated in EHCI Enhanced Host Control Interface mode and are compatible to USB 2 0 USB 1 1 and USB 1 0 devices Legacy USB support is a...

Страница 15: ...oller Please refer to section 4 3 for information regarding driver installation 2 2 6 Audio Jacks Nuvo 2000 provides audio function using Intel High Definition Audio built in in ICH8 M and Realtek ALC...

Страница 16: ...for information regarding driver installation 2 2 8 COM Ports COM1 COM2 Nuvo 2000 provides four COM ports for communicating with external devices COM1 and COM2 are located on the front panel via 9 pi...

Страница 17: ...DC Jack Nuvo 2000 offers two ways for DC power input You can supply DC power via either the DC jack or the pluggable terminal block on the front panel The DC jack is designed to use with a 12V AC DC a...

Страница 18: ...mping connection of terminal block gives a very reliable way of wiring the DC power The following table describes the pin definition of the pluggable terminal block For detail information of connectin...

Страница 19: ...output the system status to external LED indicators so that users can check how the system s running Nuvo 2000 provides a 2x6 2 0mm pitch pin header to output system status such as power HDD CF LAN w...

Страница 20: ...Reset System reset control You can connect these two pins to a non latch switch to reset the system Note Please make sure the polarity is correct when you connect the external LED indicator to the St...

Страница 21: ...onnecting a printing device The parallel port is implemented using industrial grade ITE8783 Super IO chip 40 to 85 C and has pin out via a 2x13 2 00mm pitch box header For users who need to connect a...

Страница 22: ...front panel via 9 pin D Sub male connectors COM3 and COM4 are located on SBC via 10 pin box header These COM ports are implemented using industrial grade ITE8783 Super IO chip 40 to 85 C and support...

Страница 23: ...ted by directly connecting to the IDE port of ICH8 M chipset The system recognizes the CF card installed as an IDE storage device Accordingly you can install any operating system in the CF card such a...

Страница 24: ...0MHz DDR3 SODIMM module You can also install a DDR3 1066MHz or 1333MHz SODIMM module the system will automatically adjust the memory frequency to 800MHz For information of installing a DDR3 memory mod...

Страница 25: ...7 pin SATA connector plus a 4 pin power connector A dedicated cable is shipped with Nuvo 2000 for connecting the second 2 5 HDD SSD The second HDD bracket is located on the bottom side of the chassis...

Страница 26: ...I Express Slot Nuvo 2021 provides one x4 PCI Express slot This PCI Express slot utilizes x4 PCIe link and delivers 1 GB s bandwidth It can accommodate a PCIe card with a maximal dimension of 205mm x 1...

Страница 27: ...2000 offers an option of on board 2500Vrms isolated DIO for extending application range This option provides 8 channels of isolated digital input and 8 channels of isolated digital output via a on bo...

Страница 28: ...ing table describes the pin definition of the DSub 25 pin connector Pin Pin Definition Pin Pin Definition 1 VDD 14 ISO_5V 2 DO_GND 15 DO_0 3 DO_6 16 DO_1 4 DO_7 17 DO_GND 5 DO_GND 18 DO_2 6 DO_4 19 DO...

Страница 29: ...Nuvo 2000 Series User s Manual Copyright 2013 Neousys Technology Inc All Right Reserved Page 29 of 78 2 4 Mechanical Dimension 2 4 1 Front View...

Страница 30: ...Nuvo 2000 Series User s Manual Copyright 2013 Neousys Technology Inc All Right Reserved Page 30 of 78 2 4 2 Back View...

Страница 31: ...Nuvo 2000 Series User s Manual Copyright 2013 Neousys Technology Inc All Right Reserved Page 31 of 78 2 4 3 Top View...

Страница 32: ...Nuvo 2000 Series User s Manual Copyright 2013 Neousys Technology Inc All Right Reserved Page 32 of 78 2 4 4 Bottom View...

Страница 33: ...Nuvo 2000 Series User s Manual Copyright 2013 Neousys Technology Inc All Right Reserved Page 33 of 78 2 4 5 Right View...

Страница 34: ...Nuvo 2000 Series User s Manual Copyright 2013 Neousys Technology Inc All Right Reserved Page 34 of 78 2 4 6 Left View...

Страница 35: ...via a 22 pin SATA connector A dedicated bracket is shipped with Nuvo 2000 for mounting your HDD to this SATA port To install a HDD on SATA 1 port please follow the steps listed below 1 Loose 2 screws...

Страница 36: ...Nuvo 2000 Series User s Manual Copyright 2013 Neousys Technology Inc All Right Reserved Page 36 of 78...

Страница 37: ...erved Page 37 of 78 3 Get the HDD bracket and four M3 flat head screws from the accessory box And install your HDD into the HDD bracket Note that the HDD must be placed in a right direction 4 Fasten t...

Страница 38: ...M3 L16 P head screws from the accessory box Gently slide the HDD bracket assembly into the SATA 1 connector on the SBC Three holes of HDD bracket shall be aligned with three posts on the SBC 6 Fasten...

Страница 39: ...f the chassis and is on the bottom side A dedicated cable is shipped with Nuvo 2000 for connecting the 2 5 HDD To install a HDD on SATA 2 port please follow the steps listed below 1 Put the chassis up...

Страница 40: ...rved Page 40 of 78 3 Get the SATA cable from the accessory box And connect it to SATA 2 port 7 pin SATA signals and 4 pin power on the backplane Note that the polarity of power connector must be conne...

Страница 41: ...chnology Inc All Right Reserved Page 41 of 78 5 Tilt the HDD assembly and insert the wedge of HDD bracket to the bottom cover Once it s firmly wedged push it down and fix it using a M3 flat head screw...

Страница 42: ...ICH8 M chipset and accordingly you can use a CF card for installing operating system such as Windows XP Windows 7 Linux and etc To install a CF card please follow the steps listed below 1 Open the cha...

Страница 43: ...ximal 4GB 800MHz DDR3 SODIMM module To install the DDR3 SODIMM module please follow the steps listed below 1 Open the chassis by following step 1 and 2 in section 3 1 The SODIMM socket is exposed 2 Ti...

Страница 44: ...rts 5V 33MHz 32 bit PCI bus and can accommodate PCI cards with a maximal dimension of 205mm x 105mm PCB size excluding connector To install the PCI PCIe add on card please follow the steps listed belo...

Страница 45: ...Nuvo 2000 Series User s Manual Copyright 2013 Neousys Technology Inc All Right Reserved Page 45 of 78 3 Get the M3 PW head screw from the accessory box And use it to fix your PCI PCIe add on card...

Страница 46: ...unting brackets shipped with Nuvo 2000 to mount it on the wall Neousys also offers optional DIN rail clip to mount Nuvo 2000 on a DIN rail To mount your Nuvo 2000 please refer to the information liste...

Страница 47: ...13 Neousys Technology Inc All Right Reserved Page 47 of 78 2 Fix Nuvo 2000 on the wall via the screw holes of the mounting bracket You can also take advantage of the keyhole shaped holes of the mounti...

Страница 48: ...ousys Technology Inc All Right Reserved Page 48 of 78 3 6 2 Mount your Nuvo 2000 on a Flat Surface 1 Get two wall mounting brackets and four M4 screws from the accessory box Fix the mounting brackets...

Страница 49: ...Nuvo 2000 Series User s Manual Copyright 2013 Neousys Technology Inc All Right Reserved Page 49 of 78 2 Fix Nuvo 2000 on a flat surface via the screw holes of two mounting brackets...

Страница 50: ...unt your Nuvo 3000 on the DIN Rail Neousys also provides the option of the DIN rail mounting clip You should fix the clip to Nuvo 2000 using four M4 flat head screws before mount it to a DIN rail This...

Страница 51: ...pluggable terminal block provides a reliable way for DC power input since the power wires and terminal block itself can be fasten by screws To connect DC power via the 2 pin pluggable terminal block...

Страница 52: ...elf 12V AC DC adapter for the DC jack To connect DC power via the DC jack please follow the steps listed below 1 Find your AC DC adapter with a matched DC plug The DC jack only accepts a DC plug with...

Страница 53: ...f power button is on Push the button when system is on can turn off the system If your operating system supports ATX power mode i e Microsoft Windows or Linux push the power button causes a pre define...

Страница 54: ...switch is opened the DC power is feed in and with the correct setting of Power On after Power Failure BIOS option the system is turn on 3 8 3 Power on Nuvo 2000 using an external non latched switch A...

Страница 55: ...0 using Wake on LAN function Wake on LAN WOL is a mechanism to wake up a computer system from a S3 standby S4 Hibernate or S5 system off with standby power state via issuing Subnet Directed Broadcasts...

Страница 56: ...ect Packet Nuvo 2000 can wake from S3 or S4 state when receiving a direct packet such as a ping command from another computer Please note that the Wake on Direct Packet option does not support waking...

Страница 57: ...0B 0C 78 D0 04 0A 0B 0C 78 D0 04 0A 0B 0C 78 D0 04 0A 0B 0C 78 D0 04 0A 0B 0C 78 D0 04 0A 0B 0C 78 D0 04 0A 0B 0C 78 D0 04 0A 0B 0C 78 D0 04 0A 0B 0C 78 D0 04 0A 0B 0C 78 D0 04 0A 0B 0C 78 D0 04 0A 0...

Страница 58: ...d with any modification 4 1 1 COM1 Operating Mode COM1 of Nuvo 2000 supports RS 232 full duplex RS 422 full duplex and RS 485 half duplex mode You can set the COM1 operating mode via BIOS settings Ano...

Страница 59: ...queuing are supported in several later version of operating systems Our suggestion of how to set SATA controller mode is If you re using Windows XP Linux kernel earlier than 2 6 19 or you want to use...

Страница 60: ...utput When using a PCI or PCI Express graphics card you should set a proper boot display device in BIOS in advance To set the boot display device 1 When Nuvo 2000 boots up press F2 to enter BIOS setup...

Страница 61: ...es Our suggestion for specifying the value of PCI latency timer is If the PCI devices installed are operating with low data throughput you should specify a smaller value of PCI latency timer to decrea...

Страница 62: ...re reaches the throttling on temperature CPU start to insert idle clock cycles to reduce heat generated Since Intel Atom D525 processor has a Tjmax core temperature limit of 100 C we suggest you set a...

Страница 63: ...disconnected For example if system is still on but DC power is unplugged the system is powered on next time when DC power is supplied ON System is powered on when DC power is supplied When you want t...

Страница 64: ...on your Nuvo 2000 via Ethernet connection To utilize Wake on LAN function you have to enable this option first in BIOS settings Please refer to section 3 8 4 for instructions of using WOL function To...

Страница 65: ...er Entering OS When Automatically after POST is selected the BIOS automatically stop the watchdog timer after POST Power On Self Test OK When Manually after Entering OS is selected it s user s respons...

Страница 66: ...ays to select the device You can either press F12 when system boots up to go to Boot Manager and then select one of the devices or select the boot device in BIOS settings To select a boot device in BI...

Страница 67: ...cture The following list contains the operating systems which have been tested in Neousys Technology Inc Microsoft Window XP 32 bit Microsoft Window 7 32 bit Microsoft Window 7 64 bit Ubuntu 11 04 Des...

Страница 68: ...t one mouse click 4 3 1 Install all drivers using One Click driver installation 1 Insert the Drivers Utilities DVD into a USB DVD drive attached to your Nuvo 3000 A setup utility launches and the foll...

Страница 69: ...up_v2 0 1 exe Windows 7 or Windows Vista 32 bit The recommended driver installation sequence is 1 Chipset driver x Driver_Pool Chipset_ICH8M ALL infinst_autol exe 2 Graphics driver x Driver_Pool Graph...

Страница 70: ...tem in case of system or application halts On Nuvo 2000 watchdog timer function is implemented using ITE8783 Super I O chip We provide an easy to use function library to program and utilize the watchd...

Страница 71: ...eserved Page 71 of 78 2 Click Next and specify the directory of installing related files The default directory is C Neousys WDT_DIO 3 Once the installation is finished a dialog appears to prompt you t...

Страница 72: ...tart watch dog timer Parameter None Return Value Always returns TRUE Usage BOOL bRet InitWDT SetWDT Description Set timeout value and unit for watch dog timer When InitWDT is invoked a default timeout...

Страница 73: ...n Value If the timeout value is given in correct format this function returns TRUE otherwise FALSE Usage BOOL bRet StartWDT ResetWDT Description Reset the timeout value to the value given by SetWDT If...

Страница 74: ...k resistor You need to provide a voltage to specify the logic high low state The input voltage for logic high is 5 24V and the input voltage for logic low is 0 1 5V The digital output function of Nuv...

Страница 75: ...Install WDT and DIO Library The WDT_DIO function library is delivered in the form of a setup package named WDT_DIO_Setup exe In prior to program WDT and DIO on Nuvo 1000 series you should execute the...

Страница 76: ...eserved Page 76 of 78 2 Click Next and specify the directory of installing related files The default directory is C Neousys WDT_DIO 3 Once the installation is finished a dialog appears to prompt you t...

Страница 77: ...DIO before write read any DIO port channel Parameter None Return Value Returns TRUE if initialization successes FALSE if initialization failed Usage BOOL bRet InitWDT DIReadLine Description Read a sin...

Страница 78: ...nel to be written For Nuvo 2000 ch should be a value of 0 7 value BOOL value TRUE or FALSE specifies the status of DO channel Return Value None Usage BYTE ch 3 DI channel 3 BOOL DOChValue TRUE DOWrite...

Отзывы: