Neomatica LLC. Vehicle tracker ADM333BLE GLONASS/GPS. Ver. 1.2 dd 13.07.2019
38
Command
Answer
Parameters
Description
22
TRACKSET X
The response displays a
detailed configuration of all
the set parameters of the
travel drawing
X= 0…4
Select the preset of route drawing quality.
For more details see clause 5.6.1
Selecting presets of route drawing quality
23
InTrue X,Y,Y
Example:
InTrue 0,10000,60000
InTrue X,Y,Y
Example:
InTrue 0,10000,60000
X=0 – input number (always
0);
Y
– minimum range limit in
mV;
Y=60000 – the maximum
range
limit
in
mV
(unchanged value).
Set the voltage range of the logical “1” in the
analog input.
24
InFalse X,Y,Y
Example:
InFalse 0,0,4000
InFalse X,Y,Y
Example:
InFalse 0,0,4000
X=0 – input number (always
0). Y – minimum range limit
in mV; Y – maximum range
limit in mV.
Set the voltage range of logical zero in the
analog input.
25
InInfo X
Example:
InInfo 0
Example: Input 0: InTrue
8000..15000,
InFalse
0..3000
X=0 – input number (always
0).
Request information about the input
settings.
26
INPUT
INPUT0 = 12000
Command
without
parameters
Request current measured voltage level in
the analog input (mV).