AUTOMATIC COVER CONTROL: input for potential-free contact. Depending on the status of the contact connected to it on the
automatic cover’s electric panel, this input enables you to programme a reduction of the equipment’s output current to a percentage of its
nominal value.
Fig. 19
[or]
ORP / RESIDUAL CHLORINE CONTROL (unavailable in DOMOTIC-XX PLUS models): input for potential-free contact. This input can
be used to install an external controller of the electrolysis system (ORP, RESIDUAL CHLORINE, PHOTOMETER, etc.). To that purpose
connect two cables from the potential-free contact, placed in the external controller, to the corresponding input [or] placed in the system’s
control card.
Fig. 20